A deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.
Abstract
Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.
Objective.Diffusion magnetic resonance imaging (MRI) signals are sensitive to microvascular geometry and hemodynamics, but current approaches rely on computationally intensive simulations on optical coherence tomography (OCT)–derived vascular graphs. We investigated whether three‐dimensional deep learning models can se...
Jaloliddin Rustamov, Zahiriddin Rustamov, Frédéric Lesage et al.· Physics in Medicine and Biol...· 0 citations
Purpose To evaluate, within a synthetic pulmonary-artery benchmark, whether biomarker-aware super-resolution improves hemodynamic endpoint fidelity in 4D flow MRI. Methods A 3D residual channel attention network (RCAN) was trained on 22 CFD simulations from 11 pulmonary-artery geometries with 2× spatial degradation. Th...
Aitor Zubillaga-Unsain, Adrian Lluveras-Sires, C. Caballero-Gaudes et al.· bioRxiv· 1 citation
Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing m...
Xi Chen, Jian-Chuan Yang, Hong-De Li et al.· 0 citations
PURPOSE
To propose ESPIRiT-Diffusion, a physics-guided score-based diffusion reconstruction framework incorporating multi-set ESPIRiT map-based data-consistency constraints for 8.8- and 10.7-fold accelerated joint intracranial and carotid vessel wall imaging (VWI) with an isotropic resolution of 0.6 mm3.
THEORY AND M...
Tian Zhou, Yu-Long Qi, Seng Jia et al.· Magnetic Resonance in Medici...· 0 citations
PURPOSE
Magnetic resonance elastography (MRE) is a critical non-invasive modality for quantifying tissue stiffness, but its clinical utility is limited by the high computational cost and noise sensitivity of traditional inversion techniques, such as algebraic Helmholtz inversion (AHI) and finite element methods (FEM)....
Wei-Heng Zhong, M. Urban, H. Meidani· International Journal of Com...· 0 citations
A deep learning-based automatic NPV segmentation model that demonstrates reliable volumetric assessment with minimal slice-level omission, supporting integration into routine MR-HIFU treatment workflows is developed and clinically evaluated.
Chen-Chen Bing, T. Sainio, Ari Partanen et al.· International Journal of Hyp...· 0 citations