Design and Shake-Table Testing of a Full-Scale, Six-Story Mass Timber Building with Posttensioned Rocking Walls and Buckling-Restrained Boundary Elements
Although dynamic contributions from higher modes are known to influence the force demands in mass timber rocking walls, higher-mode force and acceleration demands have not been formally addressed in a design procedure incorporating limit states at multiple intensity levels. This study assessed the design and dynamic response of posttensioned (PT) mass ply panel (MPP) rocking walls with buckling-restrained boundary elements (BRBs), referred to as MPP-BRB walls. A design approach using multiple modes to estimate system-level dynamic demands was adopted for the design of MPP-BRB walls and assessed via shake-table testing of a full-scale, six-story, mass timber building at the National Hazards Engineering Research Infrastructure (NHERI) Large High-Performance Outdoor Shake Table (LHPOST6) at the University of California, San Diego (UCSD). To meet global and local performance criteria at service, design, and risk-targeted maximum considered earthquake (
MCE
R
) seismic intensity levels, the test specimen was designed using a modal combination rule, which assumes the higher modes superimpose with a first mode governing the nonlinear response. The modal combination rule was validated through comparison of modal estimates for peak response derived using the test specimen’s modal properties identified in white-noise testing and measured story drift, story force, and floor acceleration demands. The testing program utilized ground motion records scaled to the
MCE
R
design spectrum for a hypothetical Seattle site, where ground motions were chosen to demonstrate the potential for higher-mode effects in the rocking system. After 18 tests with ground motion intensities ranging from 10% MCE
R
to 110% MCE
R
, the building exhibited negligible observable residual drifts. The MPP-BRB system behaved as intended, with the rocking wall enforcing a near-uniform distribution of story drift and the posttensioning enabling recentering. The design approach was able to represent the distribution and peak values of the experimentally observed responses, including posttensioning force stability, wall uplift, story drifts, floor accelerations, and force demands.
Recent revisions to the International Building Code (IBC 2021) have allowed high-rise mass timber shear wall structures up to 18 stories and 270 feet, reflecting the growing popularity and wide recognition of the advantages of mass timber construction. However, research on high-rise mass timber lateral force resisting...
Tian Xia, Yun-Tian Wu, Ahmed Ibrahim· Infrastructures· 0 citations
Advancing structural sustainability requires a rigorous evaluation of the economic and environmental trade-offs inherent in engineering design and material selection. To address this in sustainable construction, this paper presents a comparative study of the lateral-torsional buckling (LTB) resistance of glulam timber,...
Continuous rigid-frame bridges experience web, bottom-slab, and deck-slab deterioration in service, yet strengthening locations are rarely compared within a single structure. A 3.68-m acrylic (polymethyl methacrylate, PMMA) model of a three-span rigid-frame bridge was tested at four static load levels with a three-axle...
Deng-Qin Yu, De-Rong Ma, Xiao-Chuan Cao et al.· Buildings· 0 citations
This study aims to compare the lateral capacity and seismic performance of open-frame (OF) and infill-frame (IF) configurations in an existing four-story reinforced concrete residential building in Badung, Bali. A three-dimensional structural model was developed using SAP2000, with identical geometry, material properti...
Nyoman Gede Rio Saputra· International Journal Papier...· 0 citations
The objective of this paper is to explore the seismic performance of metal building systems when they are designed as steel ordinary moment frames (OMFs) but have wall and roof dead loads that exceed prescriptive limits in the United States’ loads standard (ASCE 7). A set of archetype frames—spanning both clear span an...
M. Nikoukalam, S. Torabian, B. Schafer· Engineering Journal· 0 citations
The geometric configuration of masonry units plays a critical role in the structural performance of load-bearing walls. Nevertheless, inefficient brick geometries remain prevalent in self-built construction with limited technical supervision, a condition frequently observed in urban areas of Peru, such as East Lima, co...
Maycol Garriazo, Luz Huingo, Diana Zavaleta· Advances in Science and Tech...· 0 citations