The AQbD-based RP-HPLC method is rapid, accurate, economical, and highly robust, making it suitable for routine quality control, stability testing, and regulatory applications in ketoconazole analysis.

Abstract

A stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative estimation of ketoconazole in bulk drug and pharmaceutical dosage forms using the Analytical Quality by Design (AQbD) framework. Critical method parameters were identified through risk assessment and optimized via Design of Experiments (DoE), ensuring robustness, reliability, and regulatory compliance. Chromatographic separation was achieved on an Agilent Zorbax SB-Aq column (250 × 4.6 mm, 5 µm) employing a mobile phase of phosphate buffer and acetonitrile (35:65, v/v) at a flow rate of 0.8 mL/min, with detection at 225 nm. Ketoconazole eluted at approximately 5.47 min within a total runtime of 15 min. Validation, performed in accordance with ICH Q2(R1) guidelines, confirmed excellent specificity, linearity, precision, accuracy, robustness, sensitivity, and reproducibility. The calibration curve was linear across 80–120 µg/mL with a correlation coefficient (R²) of 1.000. Precision studies yielded %RSD values below 2%, while recovery ranged between 99.75% and 100.07%, indicating high accuracy. Limits of detection and quantification were 0.31 µg/mL and 0.94 µg/mL, respectively. Robustness evaluation revealed negligible effects of minor variations in pH and detection wavelength. Forced degradation under acidic, alkaline, oxidative, thermal, and photolytic conditions demonstrated the method’s stability-indicating capability. Maximum degradation was observed under oxidative stress (16.14%), followed by thermal (9.34%), photolytic (8.97%), alkaline (6.71%), and acidic (6.09%) conditions, with degradation products well resolved from the analyte peak. The AQbD-based RP-HPLC method is rapid, accurate, economical, and highly robust, making it suitable for routine quality control, stability testing, and regulatory applications in ketoconazole analysis

Read PDF

Similar papers

Sep 2026

Method Development and Validation of Promethazine HCl by Using RP-HPLC and Its Forced Degradation Studies.

A simple, rapid, sensitive, and stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative determination of promethazine hydrochloride (HCl) in pharmaceutical formulations. Chromatographic separation was achieved using a SunFire® C18 colum...

Deepshikha Nirwan, Kandasamy Nagarajan, P. Grover et al. · 0 citations
Open access Sep 2026

AI-Assisted Stability-Indicating RP - HPLC Method Development and Validation for the Quantitative Estimation of Tafamidis in Bulk Drug and Pharmaceutical Dosage Forms

A stability-indicating reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the quantitative estimation of Tafamidis in bulk drug and pharmaceutical dosage forms. Chromatographic separation was achieved using a Phenomenex Gemini ODS C18 column (250 × 4.6 mm, 5 µm) with...

Badikela Rama Krishna, Challamalla Pavani, B. Vasudeva et al. · 0 citations
Open access Aug 2026

RP-HPLC Analytical Method for the Determination and Validation of Rifapentine in Bulk and Pharmaceutical Formulations

The validated RP-HPLC method is suitable for routine quality control analysis of Rifapentine in bulk and pharmaceutical dosage forms and is suitable for routine quality control analysis of Rifapentine in bulk and pharmaceutical dosage forms.

Naga Raju Panjagala Naga Raju Panjagala · 0 citations
Open access Sep 2026

Method Development, Validation and Estimation of Single Synthetic Drug Tafamidis by RP-HPLC and Green Analysis in API Form and Pharmaceutical Dosage Form

For the quantitative determination of Tafamidis in bulk and pharmaceutical dosage forms, a straightforward, accurate, precise, and environmentally friendly reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated. To achieve optimal chromatographic performance, several stationa...

H. K. Qureshi, Hurria Fatima, Amtul Zaman et al. · 0 citations
Open access Aug 2026

Development, validation, and greenness assessment of UV spectrophotometric and RP-HPLC methods for the quantitative determination of Nafithromycin

Nafithromycin is a novel ketolide antibiotic approved for the treatment of community-acquired bacterial pneumonia (CABP). The present study describes the development and validation of UV spectrophotometric and reverse-phase high-performance liquid chromatographic (RP-HPLC) methods for the quantitative determination of...

Vaishnavi Singh, Hitanshi Darji, Pravinkumar Sable · 0 citations
Open access Aug 2026

QbD-Assisted RP-HPLC Method Development and Validation for the Quantification of Sotagliflozin With LC-MS/MS Characterization of Its Degradation Products and Greenness Assessment Using AGREE and MoGAPI.

An AQbD-based approach was employed to develop and validate a reliable, stability-indicating RP-HPLC method for quantifying sotagliflozin in API and tablet dosage forms, demonstrating good linearity, precision, accuracy, robustness, and sensitivity with low LOD and LOQ values.

Ankita Gupta, Akash Sharma, G. Devi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.