To investigate the seismic performance and damage evolution of a curved continuous rigid-frame composite girder bridge under near-fault velocity pulse-like ground motions, a refined three-dimensional full-bridge finite element model was established, incorporating pile–soil interaction, expansion joint pounding, shear key damage, and nonlinear hysteretic behavior of high damping rubber bearings (HDRBs). Nonlinear time-history analyses were conducted under E1 and E2 seismic levels using near-field pulse records (short, moderate, and long periods), a near-field non-pulse record, and a far-field record. The fiber section capacity-to-demand ratio method was adopted to assess pier damage. Results show that near-field pulse-like motions govern the structural response, with long-pulse records producing the most unfavorable displacements and internal forces. Under E2, HDRBs exhibit significant yielding and hysteretic energy dissipation, effectively protecting the piers but imposing greater deformation demands on expansion joints and unseating preventers. Continuous girder piers display a transverse frame effect and a longitudinal S-shaped moment distribution with a secondary peak at the upper-middle portion due to higher modes. Rigid-frame hollow thin-walled piers exhibit S-shaped internal force distributions associated with abrupt section changes, and the tallest pier reaches a capacity-to-demand ratio of 0.82, indicating moderate yielding. The vertical seismic component amplifies transverse bending–torsion responses of curved girders through spatial coupling. The findings provide a scientific basis for ductility design and damping detailing of similar complex curved bridges.
This study numerically examines the transverse seismic response of a high-pier, long-span stiff-skeleton arch bridge equipped with transverse steel dampers (TSDs). A three-dimensional SAP2000 model represents the primary bridge members predominantly with elastic beam elements. Nonlinear behavior is concentrated in the...
The longitudinal seismic response of a high-pier long-span stiff-skeleton arch bridge is spatially asymmetric because unequal pier heights, the fixed–movable bearing arrangement, and arch–pier interaction create nonuniform force transfer paths, even when the installed fluid viscous dampers (FVDs) obey a symmetric veloc...
Nonlinear velocity dampers (NVDs) embedded in coupling beams may enhance the seismic performance of frame–core tube structures by dissipating energy and limiting structural damage. This study evaluates the seismic performance of a 20-story reinforced concrete (RC) frame–core tube building incorporating NVD-equipped cou...
Shen Liu, Bo Li, Hui Wang et al.· Buildings· 0 citations
Rectangular reinforced concrete (RC) hollow bridge piers may exhibit significant shear participation after flexural cracking and yielding, whereas their seismic responses are commonly evaluated using flexure-dominated numerical models. This study investigates the effects of axial–flexure–shear interactions on the cycli...
Ground motions recorded within 10‐15 km of a seismic source display distinct near‐field characteristics, most notably high amplitude velocity pulses associated with forward directivity and fling‐step effects. These pulses release large amounts of seismic energy within a few cycles, imposing severe demands on structures...
Ground motion directionality under pulse-like excitation significantly affects structural demand in tall buildings, but its interaction with lateral force-resisting systems is not fully quantified. This study investigates the orientation-dependent response of a rectangular reinforced concrete building subjected to puls...
C. B. Nerella, Jayaprakash Vemuri, S. Jyosyula et al.· Journal of Structural Engine...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.