Skip to content

SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI

Sep 2026 · 0 citations · 21 references
Computer Science

TL;DR

An automatic framework for continuous SA profiling from super-resolved MR volumes is proposed, extending conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment.

Abstract

Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) is used to assess trochlear morphology, but it is typically measured on a single axial MR slice with no clear guidance on which to select, making it sensitive to slice selection and landmark placement. We propose an automatic framework for continuous SA profiling from super-resolved MR volumes. Clinically acquired axial, coronal, and sagittal MR scans are combined using implicit neural representations to reconstruct a high-resolution volume. SA measurements are computed across the trochlear region using two landmark detection U-Net models. The approach was evaluated on the public fastMRI dataset and a small in-house cohort of patients with TD. Compared with conventional manual single-slice SA measurements, the proposed automated method yielded a mean absolute error of 11.6$^\circ$ while providing continuous characterization of trochlear morphology. Population-level analysis demonstrated distinct mean SA profiles between the public cohort and the in-house TD cohort, highlighting the potential of profile-based assessment to characterize TD. By reducing reliance on a single manually selected axial slice, the proposed framework extends conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment. Further validation is required. The code is available: https://github.com/wehrlimi/SA_Profile.

View source

Similar papers

Open access Oct 2026

Validation of Automated 3D MRI Knee Cartilage Measurements.

RATIONALE AND OBJECTIVES To assess the agreement between automated cartilage thickness measurements derived from three-dimensional (3D) dual-echo steady-state (DESS) magnetic resonance imaging and manual radiologist measurements. MATERIALS AND METHODS In 111 patients, cartilage thickness measurements across 21 knee s...

Mirela Kostadinova, Iman Harrou, Scherwin Mahmoudi et al. · 0 citations
Preprint Sep 2026

Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification

Background: This study evaluated interreader agreement and longitudinal performance of MRI methods for knee cartilage volume, thickness, and defect-area quantification. Methods: AI-presegmented masks from 1,189 phase III examinations underwent independent correction by two readers and adjudication. Cartilage volume, th...

Bin-Bin Yang, Yong-Mei Jian, Cheng-Lei Liu et al. · 0 citations
Open access Aug 2026

Volumetric reference data of the orbit: a deep learning MRI analysis in the German national cohort

This deep learning tool effectively resolved the bottleneck of manual segmentation, providing comprehensive orbital reference data for the German population and enabling future high-throughput epidemiological research into the associations between orbital anatomy, systemic health, and disease.

Navid Farassat, M. Reisert, S. Rospleszcz et al. · 0 citations
Open access Sep 2026

SoftSpot3D: prospective study of mobile 3D reconstruction for infants' cranial conditions.

Purpose Deformational plagiocephaly and craniosynostosis require early detection for effective and less invasive interventions. Although 3D imaging and automated analysis allow for image-based assessment by nonspecialists, current 3D imaging systems are often costly and immobile. We present SoftSpot3D, a mobile three-d...

Bo Wu, Can Kocabalkanli, Fereshteh Aalamifar et al. · 0 citations
Open access Oct 2026

Automated 3D Analysis of Hip Morphology in a Young Adult Population.

PURPOSE Although many factors contribute to the development of hip OA, structural findings, such as acetabular dysplasia, are recognized as strong contributing factors to early degenerative changes. However, conventional two-dimensional imaging cannot fully capture the joint's three-dimensional anatomy. This study aime...

M. Kamphuis, E. H. Oei, J. Runhaar et al. · 0 citations

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.