Sep 2026· Catheterization and cardiovascular interventions· 0 citations· 21 references
Medicine
TL;DR
Self-expanding THVs exhibited dynamic behavior throughout the cardiac cycle, with stent expansion during systole at both VBR and BLP levels and stent design influenced this dynamicity, as Acurate Neo2 had greater stent variability compared to Evolut THV.
Abstract
Background
Due to nitinol stent properties, self-expanding transcatheter heart valves (THVs) have the potential to adapt their frames to native annular dimension excursions during the cardiac cycle and therefore to maintain the physiological relevance of this behaviour.
Aims
To assess the in-vivo variations of THV frame dimensions during the cardiac cycle.
Methods
Patients undergoing transcatheter aortic valve replacement (TAVR) with self-expanding THV platforms enrolled in the RE-ACCESS 2 study were considered. Patients with post-TAVR four-dimensional computed tomography (4-D CT) assessment not eligible for stent frame analysis were excluded from the analysis. The THV frame dimensions were assessed at three levels: inflow edge, native virtual basal ring (VBR) and bioprosthetic leaflets plane (BLP). Measurements were performed in systolic (30° of the cardiac cycle) and diastolic (70° of the cardiac cycle) phase acquisitions for each patient. Stent expansion was reported as the difference among systolic and diastolic measurements.
Results
Among a total of 127 patients, 83 patients were considered eligible for the present analysis. Forty-nine and 34 patients received Evolut and Acurate Neo2 THV, respectively. Stent frame expansion across the cardiac cycle was encountered at VBR (median perimeter variability 0.30 mm) and BLP (median perimeter variability 0.25 mm) levels, but not at the inflow level (median perimeter variability -0.05 mm). Acurate Neo2 had greater variability compared to Evolut THVs (VBR median perimeter variability 0.50 mm vs. 0.10 mm, p = 0.02; BLP median perimeter variability 0.60 mm vs. 0.20 mm, p = 0.05).
Conclusions
Self-expanding THVs exhibited dynamic behavior throughout the cardiac cycle, with stent expansion during systole at both VBR and BLP levels. Stent design influenced this dynamicity, as Acurate Neo2 had greater stent variability compared to Evolut THV. Whether these features affect long-term THV durability remains to be determined.
BACKGROUND
Advances in transcatheter aortic valve implantation (TAVI) devices and techniques have been remarkable. Self-expanding valves (SEVs) possess the technical advantage of reposition (REP); however, research on their clinical impact remains limited.
AIMS
This study aimed to investigate the impact of REP, inclu...
Juri Iwata, Z. Arow, Akiko Masumoto et al.· Catheterization and cardiova...· 0 citations
Using a high-pressure balloon to do bioprosthetic valve remodeling (BVR) for a failed surgical non-fracturable aortic valve is thought to improve the expansion of a transcatheter heart valve (THV) during valve-in-valve transcatheter aortic valve replacement (ViV-TAVR). However, the risks and benefits of this approach r...
Y. Tsai, Ching-Wei Lee, Su-Chan Chen et al.· Catheterization and cardiova...· 0 citations
Background Patients with extremely small aortic annuli are at increased risk of residual gradients and prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR). Comparative data on contemporary valve platforms in this subset remain limited. Objectives The authors aimed to compare early clin...
Shinichi Shirai, H. Hioki, M. Yamamoto et al.· JACC: Asia· 1 citation
BACKGROUND
Patients with small aortic annuli undergoing transcatheter aortic valve implantation (TAVI) are at risk of higher residual transvalvular gradients. Evidence on the performance of new-generation intra-annular self-expanding valves in this anatomical setting remains limited.
AIMS
To evaluate the impact of an...
Matteo Casenghi, S. Corradetti, Pasquale Paolisso et al.· Catheterization and cardiova...· 0 citations
Transcatheter Aortic valve implantation (TAVI) procedure has been revolutionizing the Aortic Stenosis (AS) treatment over the last 20 years, because of its minimally invasive approach and fast postoperative recovery. However, innovation in valve material compatible with TAVI procedure present significant challenges, as...
Pramod Dorishetty, Aden Carlton, Leon Neethling et al.· Journal of Cardiovascular Tr...· 0 citations
Among patients treated with newer-generation transcatheter valves, SEV demonstrated more favorable hemodynamic performance compared with BEV, however, short- and mid-term mortality rates remained similar between the two groups.
M. Baudo, S. Sicouri, Dimitrios E. Magouliotis et al.· Journal of Cardiovascular Me...· 1 citation
For decades, a fundamental question about the difficulty of computing in high-dimensional spaces has resisted proof. New research resolves this question, removing a major theoretical obstacle to understanding the efficiency of randomized algorithms used across science and computing. The Kannan–Lovász–Simonovits (KLS) conjecture was proposed in 1995. It asks whether, for a broad class of high-dimensional […] The post Solving a 31-year-old grand challenge in mathematics – the KLS conjecture appear…
MIT News · Artificial Intelligence· news.mit.eduOct 15, 2026
A new computational approach reveals how cells communicate to assemble into tissues. This could accelerate stem cell engineering, improve disease models, and inform therapies.
Microsoft Research Blog· microsoft.comOct 15, 2026
Zero-knowledge proofs can verify computing results without rerunning workloads or exposing sensitive data. Magnetar helps bring them into the mainstream with support for standard programming languages, major speed gains, and quantum-resistant security. The post Proof-based general-purpose computing with Magnetar appeared first on Microsoft Research.
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.