Design and Implementation of a Real-time Smart Saline Monitoring, Detection, and GSM-based Emergency Notification System for Modern Healthcare Environments
2026· Irish Interdisciplinary Journal of Science & Research· Vol 10, pp. 50-60· 0 citations· 1 references
TL;DR
A Smart Saline Monitoring System based on a load cell sensor and GSM communication to achieve accurate and real-time monitoring of intravenous (IV) fluid levels and provides a low-cost, scalable solution suitable for real-time healthcare monitoring applications.
Abstract
In modern healthcare systems, continuous patient monitoring plays a vital role in ensuring safety and timely medical intervention. One of the common challenges in hospitals is the manual monitoring of intravenous (IV) saline bottles, which often leads to human error, delayed response, and potential health risks such as blood backflow and air embolism. To address these issues, this paper presents a Smart Saline Monitoring System using a load cell and GSM module for real-time and automated saline level monitoring. The proposed system employs a load cell sensor to accurately measure the weight of the saline bottle, which directly corresponds to the fluid level. The sensed data is processed using a microcontroller, where it is continuously compared with predefined threshold values. When the saline level falls below the critical limit, the system automatically triggers an alert mechanism and sends an SMS notification to the medical staff through the GSM module, ensuring immediate attention without the need for constant supervision. The system is designed to be cost-effective, reliable, and easy to integrate into existing hospital infrastructure. Experimental evaluation demonstrates that the system provides accurate measurements and quick response times under various conditions. By reducing manual workload and enhancing monitoring efficiency, the proposed solution significantly improves patient safety and operational efficiency in healthcare environments. This paper presents a Smart Saline Monitoring System based on a load cell sensor and GSM communication to achieve accurate and real-time monitoring of intravenous (IV) fluid levels. The system measures the weight of the saline bottle using a load cell interfaced with an HX711 precision amplifier. The system operates with a response time of less than 5 seconds and achieves measurement accuracy within ±2% after calibration. Experimental validation confirms reliable performance under varying load conditions. The proposed system significantly reduces manual intervention, enhances patient safety, and provides a low-cost, scalable solution suitable for real-time healthcare monitoring applications.
The findings indicate that IBIVDS can improve the responsiveness, reliability, and consistency of IV therapy monitoring while reducing dependence on continuous manual observation.
DouglasOmwenga Nyabuga, Nadia Iradukunda· Journal of Technology Inform...· 0 citations
Results show that combining scheduled dispensing with presence detection and independent remote alerting can meaningfully reduce missed and incorrect doses without requiring an internet connection or a smart phone application.
M. Srinivasa, M. Hamza, Preetham P et al.· International journal of res...· 0 citations
Intravenous infusion of medication and fluids is a critical aspect of modern medical care, particularly in acute and intensive care settings. Conventional syringe pumps typically allow administration from a single syringe and utilize force-sensitive resistors (FSRs) for pressure monitoring, which are prone to variabili...
Hari Krishnan Gurumurthy, Sudhakar Tukkaram, Bethanney Janney John et al.· Biomedical & Pharmacolog...· 0 citations
Continuous observation of vital parameters is indispensable for comatose patients, who are unable to notify caregivers
of any abnormality. Standard intensive care unit configurations are characterised by accuracy, yet they remain expensive and
immobile, and cannot easily be transported. This work presents a cost-effici...
L. Chaudhari, Swaraj Kharmale, H. Kapse et al.· International Journal for Re...· 0 citations
The results demonstrate that the proposed framework provides a reliable, cost-effective, and scalable solution for continuous remote health monitoring, with significant implications for smart healthcare systems and clinical decision support in IoT environments.
J. R. Deepak, C. Veerabathiran, J. Alsayaydeh et al.· International Journal of Adv...· 0 citations
This design is a portable multi-parameter health monitoring device based on the STM32 series microcontroller platform. It is specifically designed for real-time monitoring and anomaly alerts of three vital signs: heart rate, blood oxygen saturation, and body temperature. It naturally serves as a convenient and reliable...