Abstract
Existing EMTR methods typically adopt passive location schemes that rely on transient signals generated by faults. When faults occur at a low inception angle, the resulting traveling-wave signals are typically weak and suffer from poor detectability. Active pulse injection provides controllable excitation and improves signal identification. The transfer function similarity method achieves high accuracy; its practical application is constrained by the requirement for transient voltage at the fault point. To address these limitations, this paper proposes a fault location method based on active pulse injection and systematically investigates the characteristics of fault voltage in both frequency and time domains. First, the frequency-domain formulation of fault voltage in the reversed-time process is derived, and the applicable scope of the energy metric is evaluated. The waveform features of the reversed-time fault voltage are then analyzed to assess the similarity between the fault voltage and the injected pulse voltage, as well as the applicability of the MCCC metric. An improved IMCCC criterion is developed to quantify the similarity between the fault voltage and the forward-time voltage. Furthermore, a symmetry similarity coefficient (SSC) is defined by leveraging the inherent symmetry property of fault voltage waveforms. The four metrics were validated using reduced-scale experiments and simulation studies. All metrics achieved accurate fault location in simple lines. In complex networks, the energy metric showed significant deviation from the real fault location. The IMCCC and SSC metrics provided higher accuracy than the MCCC metric and maintained reliable fault location for grounding faults up to 300 Ω.
Fault signals in power systems often contain high-order harmonics and attenuated oscillations. which pose challenges for traditional fault time detection methods in accurately identifying the fault inception instant. To address this issue, this paper proposes an accurate fault time detection method based on Euclidean d...
To improve the accuracy and noise robustness of conventional travelingwave-
based cable fault location methods under severe noise conditions, a two-terminal travelingwave
fault location method is proposed.
The proposed method combines variational mode decomposition optimized using Improved
Sand Cat Swarm Opt...
Can Ding, Hang-Hang Guo, Liu Chao· Recent Advances in Electrica...· 0 citations
With the increasing adoption of bipolar high-voltage direct-current (HVDC) transmission lines for wind farm integration, the development of fast, accurate, and communication-independent protection schemes has become a critical technical requirement. This paper proposes a comprehensive protection algorithm within an int...
Mahyar Abasi, Vahid Davatgaran, Morteza Azizi· PLoS ONE· 0 citations
This paper presents a methodology for detecting excitation capacitor faults in self-excited induction generators (SEIGs) used in wind energy systems operating in isolated or rural areas. The proposed approach combines frequency and phase tracking with zero-crossing time rate analysis for real-time anomaly detection. Th...
A. Dilmi, A. Bouzida, Nacera Yassa et al.· Acta Polytechnica· 0 citations
Strong noise in high-voltage transformer environments can easily overwhelm weak fault signals during the switching control of simulated fault resistance networks. This interference hinders the accurate identification of fault types and levels, ultimately compromising the stability and accuracy of the switching process....
Wei-Ping Wu, Tie-Gang Yang· Journal of Physics, Conferen...· 0 citations
With the growth of emerging data centers and electric vehicles, DC power distribution and hybrid microgrids are attracting growing attention. Due to the lack of a natural zero-crossing point in DC current, reliable DC fault protection is critical. This paper introduces a transient-minimized fault protection scheme util...