Abstract
This paper demonstrates that the polarity of the current transformer (CT) is a critical determinant of directional overcurrent protection selectivity. Analytical modeling and hardware-in-loop testing confirm that a reversed CT polarity introduces a predictable 180° phase shift in the measured current. This phase inversion corrupts the directional element’s torque calculation, resulting in nondiscriminative relay behavior: failure to trip for internal faults and spurious tripping for external faults. These polarity-induced errors remain latent under steady-state conditions and manifest only during fault events, precisely when protection must perform reliably. The findings highlight the necessity of incorporating CT polarity verification into commissioning, routine maintenance, and compliance audits. They further emphasize that digital relay performance is fundamentally dependent on the integrity of its analog inputs.
The integration of STATCOM devices in transmission systems provides important operational benefits but may influence protection performance during fault conditions. This paper investigates the performance of directional relays in the presence of a STATCOM integrated into the power grid. The study was carried out using...
Youssef El Mir, A. Benslimane, J. Bouchnaif· EPJ Web of Conferences· 0 citations
This paper examines the problem of increasing the sensitivity of backup protection systems, specifically long-range backup protection systems (LRPS), at 110-220 kV branch substations (BSS) with relatively low-power power trans-formers (6.3-16 MVA). Short-circuit currents (SC) during faults on the low-voltage (LV) side...
A. V. Ukraintsev, V. Nagay, I. Nagay et al.· Известия высших учебных заве...· 0 citations
Measuring a transformer tap changer is an important part of transformer diagnostic testing, as it enables the assessment of contact transition resistance, the condition of contact elements, and the potential impact of contamination on switching reliability. The paper presents practical diagnostic cases in which an unus...
Petra Krištof, Simon Podkoritnik, Peter Osenčič et al.· 2026 International Conferenc...· 0 citations
The proliferation of inverter-based resources (IBRs) and energy storage systems in power grids has led to a decline in the short-circuit ratio (SCR) and reduced fault current magnitudes, compromising the reliability of conventional overcurrent relays (OCRs) and creating protection blind zones. To resolve these vulnerab...
General Background Substations and gas insulated substations demand highly reliable electrical systems to maintain continuous energy distribution. Specific Background Securing these high-voltage transmission units requires accurate overcurrent and circuit breaker failure mechanisms to isolate operational faults rapidly...
The modernization of power systems necessitates rigorous full-circuit testing prior to equipment commissioning. At 220 kV substations, these testing procedures are frequently hindered by the construction progress of primary equipment and stringent power outage schedules. This paper proposes a design solution for a full...
Vinh Van Nguyen, Hiếu Văn Võ, Vu Tien Tran· Journal of Science & Technol...· 0 citations