Diagnostic value of positron emission tomography using amyloid-binding radiotracers for cardiac amyloidosis: a systematic review and meta-analysis

Aug 2026 · European heart journal. Imaging methods and practice · Vol 4 · 0 citations · 52 references
Medicine

TL;DR

Amyloid PET demonstrates high sensitivity and specificity for CA detection, even though the evidence base remains limited in terms of the number and scope of available studies.

Abstract

Abstract Aims Amyloid-binding positron emission tomography (PET) tracers have emerged as a promising non-invasive tool for the diagnosis of cardiac amyloidosis (CA). This study aimed to assess the diagnostic accuracy of amyloid PET for detecting CA through a meta-analysis of diagnostic test accuracy. Methods and results PubMed, Cochrane Library, Embase, and Web of Science were searched through 16 March 2026 for studies reporting the diagnostic performance of amyloid PET for CA. The primary analysis was a bivariate random-effects (Reitsma) model yielding summary sensitivity, specificity, the summary receiver operating characteristics curve with corresponding area under the curve (AUC), and positive and negative likelihood ratios. Subgroup analyses were performed by radiotracer and by amyloid subtype. Risk of bias was assessed using QUADAS-2 and publication bias by Deeks’ funnel-plot asymmetry test. Twenty studies comprising 577 patients (407 with CA, 170 controls) met inclusion criteria, covering five radiotracers (11C-PiB, 18F-florbetaben, 18F-florbetapir, 18F-flutemetamol, and 124I-evuzamitide). In the primary bivariate model (k = 17), amyloid PET demonstrated a summary sensitivity of 0.91 (95% CI 0.83–0.96), specificity of 0.90 (95% CI 0.79–0.96), and AUC of 0.96, with low between-study heterogeneity (sensitivity I2 = 13.4%; specificity I2 = 0%). Sensitivity was high and consistent across 11C-PiB, 18F-florbetaben, 18F-florbetapir, and 124I-evuzamitide (0.96–1.00), with the exception of 18F-flutemetamol, which showed lower and heterogeneous sensitivity (0.70). Conclusion Amyloid PET demonstrates high sensitivity and specificity for CA detection, even though the evidence base remains limited in terms of the number and scope of available studies. Prospective multicentre studies in consecutive patients with suspected CA are required to establish its clinical role and standardize acquisition protocols.

Read PDF

Similar papers

Review Aug 2026

Diagnostic accuracy of plasma p-tau217 against amyloid PET: A meta-analysis of technical platform variability and ratio versus single marker comparisons

The p-tau217/Aβ42 ratio approximately doubled the diagnostic odds ratio compared with p-tau217 alone and its application in clinical practice is supported by the fact that the p-tau217/Aβ42 ratio performed much better than p-tau217 alone.

Chao-Wei Yuan, Hui Zhang, Xudong Chen et al. · 0 citations
Review Aug 2026

Diagnostic Accuracy of Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Differentiating Tumor and Bland Thrombus in Patients With Cancer: A Systematic Review and Meta-Analysis.

INTRODUCTION Differentiating tumor thrombus from bland thrombus can be challenging. This study assessed the diagnostic performance of positron emission tomography-computed tomography (PET/CT) scans in differentiating bland versus tumor thrombi in patients with cancer. METHODS We systematically searched for observatio...

Basant Eltaher, Amir Mahmoud, Kavya Balusu et al. · 0 citations
Review Open access Aug 2026

124I-Evuzamitide Positron Emission Tomography/Computed Tomography for Diagnosing Cardiac Amyloidosis: The REVEAL Nonrandomized Clinical Trial.

Importance Diagnosing cardiac amyloidosis remains challenging because current imaging approaches are limited to transthyretin amyloidosis. A noninvasive test capable of directly imaging cardiac amyloidosis from various amyloid types and in multiple organs could address an important unmet diagnostic need. Objective To...

S. Dorbala, Mathew S. Maurer, S. Cuddy et al. · 0 citations
Review Sep 2026

Amyloid-β PET Radioligands in Alzheimer's Disease: From Plaque Detection to Biomarker-Guided Patient Stratification and Therapeutic Monitoring.

A narrative review of the principal Aβ positron emission tomography radioligands and their methodological framework, including visual reads, the standardized uptake value ratio, and the Centiloid scale, which harmonized quantitative output across tracers, scanners, and protocols and may enable cross-site comparison in...

Simone Lista, L. Filippi, Enzo Emanuele et al. · 0 citations
Review Open access Aug 2026

Diagnostic accuracy of MRI and PSMA PET/CT for detection of histologically confirmed lymph node metastasis in prostate cancer: A systematic review.

OBJECTIVE To compare the diagnostic accuracy of prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) and multiparametric magnetic resonance imaging (mpMRI) for the detection of histologically confirmed pelvic lymph node metastases in patients with intermediate- and high-risk...

E. Udeh, S. Anyimba, Loius Okolie et al. · 0 citations
Review Open access Sep 2026

Radiomics Using Fused PET and CT Data for Prognostic and Diagnostic Modeling in Head and Neck Cancer: A Systematic Review and Meta-Analysis

Objectives: 18F-FDG PET/CT is central to head and neck cancer (HNC) care, yet most radiomic models use PET or CT alone. We quantified the discrimination of fused PET/CT models and what fusion adds. Methods: Following PRISMA 2020 and a registered protocol (PROSPERO CRD420261319855), seven sources were searched, suppleme...

Abdulrahman Al Mopti, A. Alqahtani, Ali H. D. Alshehri · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.