Skip to content
Preprint

Anatomically Consistent Cross-Contrast Super-Resolution of Anisotropic Brain T2w MRI

Aug 2026 · 0 citations · 38 references
Computer Science

TL;DR

VIPP-SR (View-Independent Patched Projection Super-Resolution), a cross-contrast guided super-resolution framework that restores the inter-plane resolution of an existing anisotropic T2w volume without an isotropic ground-truth T2w, is proposed.

Abstract

T2-weighted (T2w) brain MRI provides fluid-sensitive soft-tissue contrast that is important for neuro-oncology and radiotherapy planning. However, T2w scans are acquired with anisotropic voxels and appear blurred or stair-stepped on coronal and sagittal views, which obscures small structures and weakens any downstream 3D analysis. We propose VIPP-SR (View-Independent Patched Projection Super-Resolution), a cross-contrast guided super-resolution framework that restores the inter-plane resolution of an existing anisotropic T2w volume without an isotropic ground-truth T2w. VIPP-SR first trains a view-independent patched generator (VIP-GAN) to learn local T1c-to-T2w anatomical correspondence from high-resolution axial slices. The trained generator is then applied to axial, coronal, and sagittal views of the T1c volume to generate three orthogonal T2w estimates. Shape-preserving patching and deepest-skip removal reduce view-specific shortcuts, thereby constraining the generator to learn patch-local representations and enabling the zero-shot inter-plane transfer. Central to VIPP-SR, a projection-based optimization then enforces anatomical consistency across the three view-specific volumes, fusing them by balancing inter-plane self-consistency against per-view data fidelity. The generator is trained on BraTS-MET and evaluated on both the held-out BraTS-MET testing set and the BraTS-GLI cohort without retraining, assessing the cross-cohort generalizability. The results validate that VIPP-SR improves downstream segmentation over the real anisotropic T2w baseline, raising mean-label Dice from 0.330 to 0.465 on BraTS-MET and, zero-shot, from 0.473 to 0.563 on BraTS-GLI and ablation studies identify inter-plane self-consistency as the main source of the gain.

View source

Similar papers

Open access Sep 2026

Anatomically Guided Deep Learning Reconstruction of Accelerated Snapshot CEST MRI

Purpose To determine whether structural MRI information can improve reconstruction of highly accelerated 3D snapshot chemical exchange saturation transfer (CEST) MRI. Methods Fully sampled brain CEST data were retrospectively undersampled at acceleration factors (AFs) of 4, 6, 8, 10, and 12. We compared reconstruction...

E. Mensah, Abrar Faiyaz, G. Schifitto et al. · 0 citations
Conference Aug 2026

Lesion-robust longitudinal brain CT registration via MR-guided image translation

Experimental results demonstrate that the proposed lesion-robust framework for longitudinal brain CT registration based on MRguided image translation consistently outperforms conventional intensity-based registration methods as well as existing image-translation–assisted strategies in both quantitative metrics and visu...

Zijun Cheng, Hui-Xiang Zhuang, Yue Guan et al. · 0 citations
Open access Aug 2026

ALFIE: Anatomy-aware enhancement of Low FIEld 64mT T2-weighted neonatal brain MRI for structural analysis

An anatomy-aware deep learning framework for enhancement of neonatal 64mT T2-weighted MRI improves anatomical visibility while preserving native ultra-low-field contrast and enabling quantitative structural analysis support the feasibility of quantitative neonatal neuroimaging at ultra-low field.

P. Cawley, A. Uus, K. Colford et al. · 0 citations
Open access Sep 2026

Automated Brain Segmentation in Accelerated T2-Weighted MRI: Effects of Deep Learning-Based Reconstruction

Deep Resolve improved the robustness of automated brain segmentation in accelerated T2-weighted MRI, reducing cross-protocol variability and improving spatial reproducibility, with the largest reduction in reference-relative error in the most acceleration-sensitive pipeline.

J. Lasek, R. Obuchowicz, M. Strzelecki et al. · 0 citations