Coronary Mask Guided Registration (CMGR) provides an effective approach for constructing continuous-time 4D cardiac CT datasets and can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.
Abstract
Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.
The RT-SVR approach enables 4D cardiac cine with comparable bi-ventricular volumes, contrast, sharpness, and acquisition time compared to standard breath-hold cine while providing additional motion robustness.
Ye Tian, A. A. Joshi, Jon A. Detterich et al.· Magnetic Resonance in Medici...· 0 citations
Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated fr...
Yu-Hao Wang, Zhen-Dong Zhang, E. R. Criscuolo et al.· 0 citations
Liver computed tomography perfusion (CTp) imaging enables quantitative assessment of vascular dynamics but is highly susceptible to motion‐induced artifacts arising from breath‐hold variability and involuntary patient motion. These effects cause different portions of the liver to fall within the imaging field of view a...
Zhan Xu, Yao Zhao, Xin-Ru Chen et al.· Medical Physics (Lancaster)· 0 citations
The SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientat...
Arnaud Boutillon, Naomi Clarke, T. Woodgate et al.· 0 citations
BACKGROUND
Motion artifacts limit coronary CT angiography (CCTA) when mid-diastolic quiescence is short. RR-PQ estimates the low-motion interval available for reconstruction, whereas motion correction may improve image quality without changing cardiac physiology.
PURPOSE
To primarily evaluate the incremental effect o...
T. Takayanagi, T. Kondo, Takehiro Arai et al.· Journal of cardiovascular co...· 0 citations
Myocardial wall thickness is a key measurement in cardiac imaging: it guides the diagnosis of hypertrophic cardiomyopathy, informs risk stratification for sudden cardiac death, and tracks ventricular remodeling in heart failure. Obtaining this measurement reliably requires accurate three-dimensional geometry of the hea...
Amirsajjad Taleban, Bai-Hua Ren, Lei Fan et al.· Journal of imaging informati...· 0 citations