Aug 2026· Magnetic Resonance in Medicine· 0 citations· 46 references
Medicine
TL;DR
The RT-SVR approach enables 4D cardiac cine with comparable bi-ventricular volumes, contrast, sharpness, and acquisition time compared to standard breath-hold cine while providing additional motion robustness.
Abstract
Purpose
4D cardiac cine is a powerful tool for comprehensive cardiac function assessment; however, current methods rely on regular breathing and are sensitive to bulk motion and arrhythmia. We aim to develop a 4D cardiac cine approach that requires no patient cooperation and is robust to irregular breathing, bulk motion, and cardiac arrhythmia.
Methods
2D real-time (RT) spiral bSSFP with synchronized ECG was acquired in 4 cardiac orientations. In each orientation, the 2D slice was "swept" across the heart to provide volume coverage. Retrospectively gated slice-to-volume reconstruction (SVR) was then performed to reconstruct 4D cine with 1 mm3 voxel size and 25 cardiac phases. RT-SVR and clinical standard breath-hold short-axis cine were acquired in 19 subjects, including 4 arrhythmia and 2 myocardial infarction patients. Biventricular volumes were measured, and blood-myocardium contrast and boundary sharpness scores were compared.
Results
The RT-SVR approach successfully provided 4D cardiac cine for all subjects. Acquisition time was 8:33 ± 1:01 min and 8:27 ± 2:06 min (p = 0.85), blood-myocardium contrast ratio was 2.30 ± 0.58 and 2.38 ± 0.59 (p = 0.33), boundary sharpness was 1.11 ± 0.46 and 1.18 ± 0.53 (p = 0.04), for RT-SVR and breath-hold cine, respectively. Bi-ventricular volumes had good agreement, with an ejection fraction bias of -4.02% (p < 0.05) and -2.30% (p = 0.10) for left and right ventricles, respectively.
Conclusion
The RT-SVR approach enables 4D cardiac cine with comparable bi-ventricular volumes, contrast, sharpness, and acquisition time compared to standard breath-hold cine while providing additional motion robustness. This approach may be beneficial in patients that are non-cooperative, children, and those with irregular breathing and/or arrhythmia.
The SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientat...
Arnaud Boutillon, Naomi Clarke, T. Woodgate et al.· 0 citations
Coronary Mask Guided Registration (CMGR) provides an effective approach for constructing continuous-time 4D cardiac CT datasets and can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.
Yuang Wang, Shuo Wang, Chang-Yu Chen et al.· 0 citations
Cardiac strains provide significant information to evaluate cardiac performance. They can be evaluated using full field voxel-wise displacements measured, for example, using displacement encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI) or from features and textures that are measured using Cine M...
Mohammad Naqizadeh Jahromi, Rodrigo Menna Costa, Augusto Delavald Marques et al.· Biomechanics and Modeling in...· 0 citations
DL Cine enables rapid and diagnostically robust quantification of biventricular size and function in pediatric patients, including those with congenital heart disease, and optimally balances efficiency and image quality with 3-RR acquisitions.
Jonathan Kochav, Jun-Jie Ma, S. Jambawalikar et al.· Journal of Cardiovascular Ma...· 0 citations
CineDiff enabled high-quality reconstruction of highly accelerated 2D RT cine CMR and reduced block-like artifacts and preserved finer anatomical detail compared with traditional compressed sensing and a variational network method, termed CineVN.
Xuan Lei, Philip Schniter, Juliet Varghese et al.· 0 citations
Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring.
Prakash Kumar, R. Ramasawmy, A. Javed et al.· Journal of Cardiovascular Ma...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.