Skip to content

The Effect of Quantization on Clinical Benchmarks: Accuracy and Safety Across Model Families

Sep 2026 · 0 citations · 9 references
Computer Science

TL;DR

INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.

Abstract

Quantization enables deployment of large language models on resource-constrained clinical edge devices, but its effect on clinical accuracy and safety remains understudied. We evaluate five 7-8B parameter models at FP16, GPTQ-INT8, and GPTQ-INT4 precision across five benchmarks: MedQA, MedMCQA, Med-HALT, a risk-stratified sample of HealthBench, and MedSafetyBench. The study jointly varies quantization bit width, model family, and clinical task type, with explicit risk stratification and safety measures. INT8 GPTQ is universally safe (max. degradation -1.9%-1.9%), while INT4 degradation is substantial and model-dependent: BioMistral-7B, clinically fine-tuned, loses 19.7% on MedMCQA, more than any general-purpose model, showing clinical fine-tuning does not confer compression robustness. MedMCQA degrades more than MedQA under INT4; Med-HALT is largely unaffected. On HealthBench's emergency-risk subgroup, Qwen2.5-7B degrades by 26.8% under INT4, suggesting high-risk scenarios are disproportionately vulnerable to compression. On MedSafetyBench, the model family dominates over precision (refusal rates range 10.2%-74.9% at FP16), though Qwen2.5-7B (-17.8%) and Meditron-7B (-28.3%) show substantial INT4 safety degradation; notably, Qwen2.5-7B is simultaneously the most accuracy-robust model, demonstrating that accuracy and safety robustness are independent properties. We additionally test two recovery methods, clinical calibration substitution and QLoRA fine-tuning, both producing the same trade-off: MedMCQA recovers while MedQA further degrades, indicating recovery strategies require task-specific validation rather than being assumed universally beneficial. These findings indicate INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.

View source

Similar papers

Sep 2026

Generalized post-training quantization for medical image segmentation foundation model.

Medical image segmentation foundation models (MedFMs) perform strongly across diverse imaging modalities, but their large size and computational demands hinder deployment in resource-limited clinical settings. Lightweight fine-tuning is impractical given the high training cost of MedFMs, and the efficiency benefits of...

Peng Huang, Ao-Zhong Zhang, Peng-Hang Yin et al. · 0 citations
Review Open access Sep 2026

Fine-tuning a compact large language model on real-world cases yields diagnostic performance comparable to flagship models in rheumatology.

BACKGROUND Large language models (LLMs) show strong potential in medical applications. However, most leading models are closed-source and accessible only via cloud-based APIs (application programming interfaces), raising privacy and compliance concerns when handling sensitive clinical data, while high-performing open-s...

Guanhong Yao, U. Wong, Hai-Hong Yao et al. · 0 citations
Preprint Aug 2026

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone, and summarizes these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axi...

Xingtao Lin, Hangqi Ren, Caiwan Sun et al. · 0 citations
#natural language process... Preprint Sep 2026

MedSNIP: Building and Benchmarking Snippet-Level Granularity for Medical Fact Verification

Across MedSNIP-Bench, HealthFC, and MedHallu, snippet-level verification preserves or improves false-class F1, with gains concentrated where answers are long enough to fragment and where the verifier is strong enough to exploit the recovered structure.

Hasan Iqbal, Sarfraz Ahmad, Hyunjae Kim et al. · 0 citations
Sep 2026

MEDAL: Sequential adapter learning for privacy-preserving multicenter clinical language models.

MedAL is a scalable method for fine-tuning LLMs across many health systems without sharing patient-level data, enabling high-performance local models for reasoning over clinical notes and may also be useful for training multimodal healthcare AI models.

Ahmed Bakr, A. Garcia-Agundez, Travis Atkison et al. · 0 citations
Open access Sep 2026

Diagnostic Accuracy and Alignment With Human Reader Responses Across Five Large Language Models on Complex Clinical Case Challenges

Because a model can outperform clinicians in aggregate yet fail where oversight is least likely to detect it, evaluation of clinical AI should weigh error structure alongside accuracy.

R. Bellocco, L. Soraci, Lorenzo Lo Cicero et al. · 0 citations

Related blog posts

MIT News · Artificial Intelligence Aug 27, 2026

Looking beyond natural sequences

A new machine-learning framework aims to improve the success rate of computational protein design while moving away from results that reproduce sequences found in nature.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.