Sep 2026· Physics in Medicine and Biology· Vol 71, pp. 195030· 0 citations· 59 references
MedicinePhysics
TL;DR
DiffINR shows high robustness to data distribution shifts at test time, including dataset changes, limited-angle setting variations, and different MRI sampling sparsity levels, and achieves fast and accurate deformation-driven volumetric image estimation.
Abstract
Objective. We propose DiffINR for rapid deformation-driven estimation of patient-specific target volumes from limited measurements. DiffINR uses a coordinate-based implicit neural representation (INR) to estimate a dense deformation vector field (DVF) that warps a high-quality prior volume (source) to the target anatomy, with patient-specific INR initialization provided by a population-based conditional hyperdiffusion model. Approach. During offline training, INRs were optimized on fully sampled source-target image volume pairs to represent DVFs. A Transformer diffusion model, hyperdiffusion, learned the distribution of the resulting INR weights. The model was jointly conditioned on anatomical features extracted from the training source and target volumes by a foundation model and on features encoded directly from limited measurements. At inference, hyperdiffusion generated INR initial weights, which were further fine-tuned by patient-specific optimization using measurement-domain fidelity and DVF-smoothness losses. We evaluated DiffINR on two tasks: cone-beam computed tomography (CBCT) estimation from limited-angle x-ray projections and real-time volumetric magnetic resonance imaging (MRI) estimation from ultra-sparse k-space data. Main Results. For orthogonal-view 90° CBCT estimation, DiffINR achieved a structural similarity index measure (SSIM) of 0.962 ± 0.021, relative error of 6.84% ± 1.70%, and target registration error of 3.61 ± 1.27 mm, outperforming the iterative methods, population-based models, and randomly initialized INR baselines. For volumetric MRI estimation with 13 radial spokes per slice, DiffINR achieved an SSIM of 0.985 ± 0.007, Dice coefficient of 0.89 ± 0.04, and center-of-mass error of 1.30 ± 1.09 mm. DiffINR showed high robustness to data distribution shifts at test time, including dataset changes, limited-angle setting variations, and different MRI sampling sparsity levels. Test-time runtime was 23 s for CBCT estimation and 27 s for MRI estimation, compared with 795 s and 928 s, respectively, for INR optimization from scratch. Significance. By combining hyperdiffusion-based INR initialization with patient-specific data consistency, DiffINR achieves fast and accurate deformation-driven volumetric image estimation.
MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning, is proposed, and results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.
Jia-Ying Li, Paolo Remagnino· International Conference on...· 0 citations
FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.
T. Gottwald, Michelle Bruch, M. Hassan et al.· 0 citations
Pretrained models outperformed the non-pretrained baseline and cWDM achieved the strongest results across both quantitative and qualitative evaluation, suggesting that harmonized preprocessing may enhance cross-domain deployment.
Flow matching methods for imaging inverse problems typically incorporate measurements through network conditioning or guidance during sampling. Neither approach explicitly applies the forward operator within the learned conditional velocity field. We develop a principled measurement-conditional velocity parameterizatio...
Shirin Shoushtari, Edward P. Chandler, Xiao Shi et al.· 0 citations
This work introduces a novel SFUDA framework built on Symmetrical Flow Matching, a unified generative model that segments an input image and synthesizes a source-like image from a mask within the same learned flow that outperforms SFUDA baselines and is competitive with conventional UDA methods.
Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps.
Davide Evangelista· 1 citation
Related blog posts
Microsoft Research Blog· microsoft.comNov 16, 2026
AI coding agents are increasingly help developers fix bugs and build features largely on their own, but every interaction with their models consumes tokens. In each session, an agent sends instructions, tool descriptions, and session history to its model. Most efforts to reduce this cost focus on individual tasks. Yet developers return to the same […] The post TokenEconomizer: Learning from Experience to Make AI Coding Agents More Efficient appeared first on Microsoft Research.
MIT scientists developed a training method to generate models that simulate the effects of human activities on climate much more quickly than other approaches.