Skip to content
Open access

Determinants of effective height in morphologically normal tricuspid aortic valves: A computed tomography-based anatomical study.

Aug 2026 · Interdisciplinary cardiovascular and thoracic surgery · 0 citations
Medicine

TL;DR

It is demonstrated that effective height is strongly associated with geometric height, which remained independently associated after adjustment, along with aortic annular and sinotubular junction diameters.

Abstract

Objectives

To analyse the relationship between effective height and other morphological parameters of the aortic valve complex when the aortic valve is closed.

Methods

We retrospectively analysed 105 patients (mean age 70.7±10.1 years) with morphologically normal aortic valves, roots, or ascending aortas who had undergone electrocardiography-gated cardiac computed tomography as a screening test of the coronary artery, from August 2014 to December 2018. Parameters of the aortic valve complex configuration (effective height, geometric height, aortic annular diameter, sinus of Valsalva diameter, sinotubular junction diameter, commissure height, and Valsalva height) in diastole were measured using Ziostation2 software. Pearson's correlation was used to evaluate the associations between the effective height and other parameters. Multiple regression analysis was performed to evaluate the variables independently associated with effective height.

Results

Significant associations were observed between the effective height and geometric height, sinus of Valsalva diameter, sinotubular junction diameter, commissure height, and Valsalva height (all p < 0.001) but not between effective height and aortic annular diameter (p = 0.227). Multivariable analysis showed that geometric height, aortic annular diameter, and sinotubular junction diameter were independently associated with effective height (all p < 0.001; overall model fit: R2=0.739).

Conclusions

Our findings demonstrate that effective height is strongly associated with geometric height, which remained independently associated after adjustment, along with aortic annular and sinotubular junction diameters. These results provide quantitative in vivo evidence regarding the anatomical determinants of effective height in morphologically normal tricuspid aortic valves and may serve as anatomical reference data for future research on individualised approaches to aortic valve repair.

Read PDF

Similar papers

Open access Apr 2026

Avaliação da Velocidade da Onda de Pulso por Meio de Ecocardiografia Transtorácica em Crianças com Válvula Aórtica Bicúspide

Although aortic elasticity parameters were normal with conventional measurements based on ascending aorta diameters, PWV measurements with the same device were significantly higher without the need for an additional apparatus or program, and aortic stiffness increased in the BAV group.

Kerem Ertaş, Özlem Gül · 0 citations
Aug 2026

Vendor-independent Aortic Valve Calcium Scoring in Patients with Discordant Echocardiographic Criteria of Severe Aortic Stenosis.

Purpose To apply a vendor-neutral Agatston score (vnAS) for aortic valve calcification across multiple CT systems and to aortic stenosis severity classification. Materials and Methods Anthropomorphic phantoms with varying degrees of calcification were scanned using seven different CT systems and a reference electron-beam CT system to determine the vnAS. The vnAS was calculated using a regression model, whose performance was evaluated by both the coefficient of determination and analysis of variance. The vnAS was subsequently validated on a retrospective patient sample from eight international centers. Thresholds of severe aortic valve stenosis were defined as 1274 and 2065 AU for women and men, respectively. Results The Agatston scores from all CT systems were strongly correlated with that of the reference system (R2 > 0.932). On the basis of their echocardiographic findings, 183 of 831 (22.0%) patients (mean age ± SD, 77 years ± 10; 351 of 831 [42.2%] women) had discordant echocardiographic aortic valve stenosis findings. Among women with discordant results, the vnAS was higher than the traditional aortic valve calcium score (median, 1693 AU [IQR, 908-2513 AU] vs 1181 AU [IQR, 726-1964 AU], respectively; P < .001). Similar findings were observed for men (median, 2658 AU [IQR, 1894-3822 AU] vs 2056 AU [IQR, 1408-3056 AU], respectively; P < .001). Using the vnAS, 8.5% of women and 17.8% of men with discordant echocardiographic findings were reclassified into the severe aortic stenosis group. Conclusion A previously developed calibration tool, the vnAS, was validated and reclassified patients with discordant echocardiographic findings into the severe aortic stenosis group. Keywords: CT, Echocardiography, Percutaneous, Cardiac, Valves, Calcifications/Calculi, Technology Assessment, Vendor-neutral Agatston Score, Aortic Stenosis, Aortic Valve Calcification, Phantoms Supplemental material is available for this article. © RSNA, 2026 See also commentary by Jaltotage and Leipsic in this issue.

M. Dobrolinska, N. R. van der Werf, M. Greuter et al. · 0 citations
Review Open access Aug 2026

Advanced 3D echocardiographic assessment of the aortic valve and aortic root complex: a repair-oriented perspective

Three-dimensional echocardiography, particularly transoesophageal 3DE, has become an essential imaging modality for integrating anatomical and functional information and plays a pivotal role in promoting a repair-oriented approach to the management of aortic valve disease.

T. Viva, C. Fiore, R. Dulgheru et al. · 0 citations
Open access Aug 2026

Left Ventricular Longitudinal Strain Is Associated with Ascending Aortic Diameters in Healthy Adults—A Detailed Single-Center Retrospective Analysis from the Three-Dimensional Speckle-Tracking Echocardiographic MAGYAR-Healthy Study

Even in the absence of cardiovascular pathology, a finely tuned interaction can be observed between regional LV deformation, especially with LV-LS and the size of the ascending aorta in healthy individuals.

A. Nemes, N. Ambrus, C. Lengyel · 0 citations