Sep 2026· International Journal of Applied Power Engineering (IJAPE)· Vol 15, pp. 1233· 0 citations· 22 references
Abstract
Precise electrical cable representation is crucial for examining surge transient overvoltages in medium voltage (MV) motor systems. These brief overvoltages, initiated by swift switching actions, may induce substantial insulation strain, equipment degradation, and potential system failures. This study explores the influence of different power cable modeling techniques on transient overvoltage characteristics in MV motors during switching operations. Various modeling techniques, such as aggregated parameter, spread parameter, and frequency-dependent models, are evaluated for their effectiveness in inward capturing transient phenomena. Simulation studies using industry-standard electromagnetic temporary (EMT) assessment instruments evaluate the effect of these simulation methods on voltage spikes, shape distortions, and rise times. The discoveries indicate that exact electrical wire depiction is pivotal in molding, fleeting reactions, emphasizing the significance of choosing suitable simulation methods for efficient insulation coordination and system protection. This research provides valuable guidance for power system engineers, helping them mitigate transient overvoltage risks and improve the reliability of MV motor applications. Also, this study demonstrates electrical cable simulation that can impact the advice and verdicts obtained from moderate voltage motor.
The transition from point-to-point HVDC links to multiterminal HVDC (MT-HVDC) grids increases the need to understand how the interruption of DC current shapes transient dielectric stress on connected cable systems. This paper develops a compact parameterization of the DC circuit breaker–cable interface in a reduced 525...
T. Karmokar, Arjan Van Schijndel, Marjan Popov· 2026 International Conferenc...· 0 citations
Introduction. In 6-10 kV electrical networks with high-power induction motors, emergency modes accompanied by voltage sags, motor starts, and self-starts significantly reduce the reliability of power supply. The selection of the Automatic Transfer Switch (ATS) operating speed is of particular importance, as the superpo...
B. A. Korobeinikov, A. M. Oppakhodzhaev, D. I. Sidorov· Вестник Северо-Кавказского ф...· 0 citations
Fast-switching transients and high dv/dt associated with PWM inverters exacerbate the reflected-wave effects in the motor feeder cable. This leads to higher motor-side overvoltages, which increase the stress on the motor winding insulation, potentially accelerating insulation degradation and increasing the risk of part...
Fawzy A. Abdo, Mehmet Güleç, Kotb B. Tawfiq et al.· Machines· 0 citations
Reliable operation of medium-voltage distribution networks critically depends on the integrity of cross-linked polyethylene (XLPE) insulated cables. This paper proposes a diagnostic methodology that integrates leakage current (LC) measurement with phase-resolved partial discharge (PRPD) analysis to assess cable insulat...
K. Janprom, Sittadach Morkmechai, Natchanun Prainetr et al.· International Journal of App...· 0 citations
Wide-bandgap (WBG) inverter drives impose repetitive high-frequency voltage stress, accelerating insulation degradation and increasing the probability of short-circuit faults in cables and machine windings. However, existing online diagnostic approaches face significant deployment barriers due to their sensitivity to e...
Yue Yu, Hu-Jun Peng, S. Steentjes· 2026 International Conferenc...· 0 citations
Transformer energisation in offshore High-Voltage Alternating Current (HVAC) transmission systems can result in significant transient and temporary overvoltages due to the interaction between transformer magnetising inrush currents and network resonances. A detailed Electromagnetic Transient (EMT) model comprising a Th...
M. Jyothi, C. V. K. Bhanu· International Journal of Ele...· 0 citations