Skip to content
Review Open access

Diagnostic Accuracy of Artificial Intelligence-Based Electrocardiography for the Detection of Heart Diseases: A Systematic Review and Meta-Analysis

Sep 2026 · Diagnostics · Vol 16 · 0 citations · 43 references
Medicine

TL;DR

For HF/LVSD, AI-ECG shows consistent and reproducible accuracy against echocardiography, and this estimate proved robust to the exclusion of studies at high risk of bias.

Abstract

Background/Objectives: Electrocardiography augmented by artificial intelligence (AI-ECG) has been put forward as an inexpensive, scalable means of identifying a wide range of cardiac disorders, but reported performance differs markedly with the condition targeted, the algorithm, and the reference standard. Our pre-specified primary objective was to estimate the diagnostic accuracy of AI-ECG for heart failure/left ventricular systolic dysfunction (HF/LVSD); accuracy in other cardiac conditions was examined condition by condition, and a cross-condition estimate was computed only as a secondary, descriptive summary. Methods: Following the PRISMA-DTA statement, we systematically reviewed diagnostic test accuracy (DTA) studies indexed in PubMed, Scopus, Web of Science, and Embase from inception to 31 March 2026. Eligible records were primary cohort or case–control diagnostic studies applying an AI algorithm to the ECG against an acceptable reference standard, with a reconstructable 2 × 2 table. Screening, extraction, and QUADAS-2 appraisal were performed independently in duplicate. Sensitivity and specificity were pooled with a bivariate random-effects (Reitsma) model whenever four or more studies shared a target condition, with the corresponding hierarchical summary receiver operating characteristic (HSROC) curve; subgroups with fewer than four studies were synthesised descriptively. Pre-specified sensitivity analyses excluded studies at high risk of bias. Certainty was graded with GRADE for test accuracy. Results: Twenty studies (155,442 ECG–reference pairs) were included and 12 (125,568 ECG–reference pairs) entered the quantitative synthesis. In the pre-specified HF/LVSD analysis (k = 5; n = 101,875), pooled sensitivity was 0.86 (95% confidence interval [CI], 0.80–0.90) and pooled specificity was 0.79 (95% CI, 0.70–0.85), with an HSROC area under the curve (AUC) of 0.89; restricting the analysis to the three studies at low risk of bias gave a sensitivity of 0.83 (95% CI, 0.81–0.85) and a specificity of 0.82 (95% CI, 0.75–0.87). The estimated between-study correlation between logit-sensitivity and logit-specificity was −0.86, indicating a strong implicit threshold effect that the bivariate/HSROC framework accommodates. Descriptive subgroup results indicated high accuracy for atrial fibrillation (median sensitivity 0.96, median specificity 0.94; k = 2) and inconsistent performance across coronary disease and acute coronary syndromes (median sensitivity 0.80, median specificity 0.85; k = 2). The secondary cross-condition estimate (k = 12) was 0.84 (95% CI, 0.77–0.89) for sensitivity and 0.87 (95% CI, 0.79–0.93) for specificity (HSROC-AUC 0.92); because it spans heterogeneous targets it is reported as a descriptive summary only. Overall risk of bias was low in 3/20 studies, unclear in 4/20, and high in 13/20, chiefly in the index test and reference standard domains. The Deeks test indicated funnel asymmetry (p = 0.022), which in DTA reviews commonly reflects heterogeneity in true accuracy rather than publication bias. Conclusions: For HF/LVSD, AI-ECG shows consistent and reproducible accuracy against echocardiography, and this estimate proved robust to the exclusion of studies at high risk of bias. Evidence for other cardiac conditions remains condition specific and less certain. Wider adoption would benefit from prospective external validation against guideline-based reference standards, independent adjudication, and transparent reporting of 2 × 2 data at pre-specified operating points.

Read PDF

Similar papers

Review Open access Aug 2026

Artificial intelligence–enabled electrocardiography for detection of left ventricular diastolic dysfunction: a systematic review and meta-analysis

Artificial intelligence-enhanced electrocardiography demonstrated good diagnostic performance for detecting LVDD and may support future rule-out or risk-enrichment strategies in selected populations, however, current evidence remains insufficient to support routine clinical implementation.

Johann A. C. Edjimbi, Nisarg Shah, L. Donisi et al. · 1 citation
Open access Sep 2026

Limited Clinical Utility of Artificial Intelligence-Enabled Electrocardiogram for Bicuspid Aortic Valve Detection: Uncovering Limitations for Specific Cardiac Phenotypes

Bicuspid aortic valve (BAV) is the most common congenital heart defect, associated with a lifetime morbidity burden exceeding 80% and an estimated 7% probability of transmission to first-degree relatives. Hence, echocardiographic screening of relatives is recommended. The aim of our study is to develop an artificia...

Manuel A. Montoya-Hernández, Francisco López-Jiménez, T. Poterucha et al. · 0 citations
Review Open access Aug 2026

Artificial Intelligence-Enabled Electrocardiograms and Pregnancy-Related Cardiomyopathy: A Systematic Review and Diagnostic Meta-Analysis.

BACKGROUND Pregnancy-related cardiomyopathy (PRCM) is a leading cause of maternal death in the United States. PRCM symptoms often overlap with those of normal pregnancy and the lack of validated screening tools limits early recognition and contributes to diagnostic delays. Multiple artificial intelligence-enabled elect...

O. Adesanya, Osaivbie E. Irorere, K. Young et al. · 0 citations
Review Open access Aug 2026

Artificial intelligence in electrocardiogram interpretation for cardiovascular diagnosis and risk prediction: a systematic review of evidence through May 2026

Artificial intelligence-enabled electrocardiogram interpretation shows strongest support for arrhythmia detection and automated ECG classification, while structural disease screening and prognostic modeling remain promising but less mature.

Mohamed Elhussain, Esra M. Abdalla, Ragda Ali et al. · 0 citations
Review Open access Aug 2026

Clinical applicability of artificial intelligence electrocardiogram interpretation in Brugada syndrome: a diagnostic accuracy meta-analysis.

INTRODUCTION Artificial intelligence electrocardiogram (AI-ECG) interpretation has emerged as a promising approach to identify Brugada syndrome (BrS). This review sought to investigate diagnostic viability and clinical applicability of AI-ECG interpretation models for detecting BrS. METHODS A systematic search (PubMe...

K. Cuandra, C. D. Tristan, Indah Kurnia Hutabarat et al. · 0 citations
#explainable ai Review Open access Sep 2026

A systematic survey of artificial intelligence methods for ECG-based cardiovascular disease prediction

This systematic review examines how artificial intelligence methods are being applied to ECG-based cardiovascular disease prediction, with particular attention to data handling practices, modeling approaches, interpretability techniques, and evaluation strategies, to accelerate the development of reliable, fair, and cl...

T. M, Soumyashree M. Panchal, Prasanna Lakshmi G. S · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.