Skip to content
Open access

Transient Impedance Fitting-Based Distance Protection for Transmission Lines with Hybrid Renewable Integration

Sep 2026 · Energies · 0 citations · 25 references

Abstract

The hybrid operation of grid-following (GFL) and grid-forming (GFM) renewable energy units can lead to phase-reference inconsistencies and distorted transient impedance trajectories, which in turn cause maloperation or failure-to-operate of conventional distance protection. To address this issue, this paper proposes a novel distance protection method based on transient impedance fitting. First, a dynamic phase transformation is applied to map the currents of GFL units into a unified reference frame, enabling consistent representation of heterogeneous currents from the hybrid renewable energy station. Second, a transient equivalent impedance model is established based on the transient voltage-current relationship of the transmission line, revealing the influence mechanisms of the rates of change in current amplitude and phase angle on the transient additional impedance. Finally, the magnitude of the transient impedance within a short post-fault data window is selected as the fitting object. The least-squares method is employed to extract the linear fitting slope and intercept, which characterize the evolution trend and initial position of the transient impedance trajectory, respectively, thereby forming the criteria for distinguishing internal and external faults. Simulation results demonstrate that the proposed method correctly identifies fault sections under various fault locations, transition resistances, and renewable power output conditions, with the protection decision completed within 15 ms. The proposed method effectively overcomes the susceptibility of conventional distance protection to maloperation and failure-to-operate in scenarios with high renewable energy penetration.

Read PDF

Similar papers

Open access Sep 2026

Voltage–Current Curve-Based Line Protection for Renewable Energy Systems with Grid-Forming Inverters

The increasing penetration of inverter-based renewable energy resources is reshaping transmission-line fault characteristics and weakening protection criteria designed for synchronous-generator-dominated grids. This paper proposes an internal-fault identification scheme based on voltage–current coupling characteristic...

Long-Fei Ren, Xiao He, Wei-Zhen Li et al. · 0 citations
Open access Sep 2026

Impact of Grid-Following and Grid-Forming Inverter Integration on Bus Impedance Characteristics of Power Grids

The increasing replacement of synchronous generators (SGs) by grid-following (GFL) and grid-forming (GFM) inverters is reshaping the dynamic bus characteristics of modern power systems. This transition makes a fixed ideal-voltage-source representation of the upstream main grid increasingly inadequate, especially when t...

Ya-Lei Yuan, Xiang Wang, Shi-Wang Gu et al. · 0 citations
Open access Aug 2026

Transient Power Angle Stability Analysis of Grid-Forming Converters Under Resistive Short-Circuit Faults

This paper examines the transient power-angle stability of grid-forming converters (GFMs) subjected to grid faults. Existing studies commonly simplify the network as a purely inductive line and use ideal fault assumptions, which makes it difficult to describe how practical fault conditions influence power transmission...

X.-Y. Deng, X.-L. Zhu, Y. Hu et al. · 0 citations
Open access Sep 2026

Impedance-Based Small-Signal Harmonic Stability Analysis of a STATCOM in Power Systems with Renewables

With the increasing penetration of inverter-based resources (IBRs), maintaining converter-driven stability has become a critical challenge. Static synchronous compensators (STATCOMs) are widely deployed for voltage regulation through rapid injection or absorption of reactive power, making their capability crucial in IB...

JooYong Jung, NamKyu Kim, Soo Hyoung Lee et al. · 0 citations
Open access 2026

Low Voltage Ride-through Control of Grid-Forming/Grid-Following Hybrid System Based on Current Limiting Feasible Region

: The deployment of grid-forming converters (GFMC) in weak-grid renewable energy stations can provide voltage support for grid-following converters (GFLC). However, the coupling between the two types of converters may cause the voltage-support capability of the GFMC to be constrained by its overcurrent capacity during...

Yuxuan Chen, Ying-Qi Yi, Meng-Yan Ni et al. · 0 citations
Open access Aug 2026

Adaptive Virtual Impedance Control for LVRT of Grid-Forming Energy Storage PCS in HVDC Receiving-End Grids

With the large-scale integration of high-voltage direct-current (HVDC) transmission systems, the receiving-end AC grid exhibits weak voltage-support capability. Consequently, grid-forming (GFM) battery energy storage converters are required to satisfy both current-limiting and voltage-support requirements during fault...

Pu Liu, Zhao-Fan Wang, Yong-Peng Shen et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.