Jul 2026· IEEE Power & Energy Society General Meeting· pp. 1-5· 0 citations· 14 references
Engineering
TL;DR
Comparative analyses with convolutional neural network, long-short-term memory, and multi-layer perceptron architectures, demonstrate that the proposed model delivers superior classification performance, particularly under the most stressed condition with 70% photovoltaic penetration and 5% harmonic distortion.
Abstract
The increasing integration of distributed energy resources introduces new challenges for accurate fault detection and classification in distribution networks. This paper presents a topology-aware graph convolutional network-based model for fault classification under inverter-induced harmonic distortion. The model uses pre-fault and post-fault voltage and current phasors, including harmonic components, mapped to the IEEE 34-bus system topology. The simulation data generated in OpenDSS encompass varying levels of penetration of solar photovoltaics (30%, 50%, 70%) and current total harmonic distortion (0%, 1%, 3%, 5%) across multiple fault types: single line-to-ground, line-to-line, double line-to-ground, and three-phase-to-ground. A differential evolution algorithm is employed to optimize the hyperparameters of the network, resulting in a three-layer model that achieves an F1-score of 0.98. Stress testing across scenarios confirms high robustness and minimal class confusion. The results demonstrate that a graph convolutional network-based model can effectively classify distribution faults under varying photovoltaic penetration levels and harmonically distorted conditions. Comparative analyses with convolutional neural network, long-short-term memory, and multi-layer perceptron architectures, demonstrate that the proposed model delivers superior classification performance, particularly under the most stressed condition with 70% photovoltaic penetration and 5% harmonic distortion.
High-voltage direct current (HVDC) transmission systems face protection challenges due to the absence of natural current zero-crossings and the rapid rise of fault currents. This paper proposes a hierarchical fault detection and classification framework for multi-terminal HVDC networks that combines transient feature e...
Kshitij Niraula, Manilka Jayasooriya, M. N. Iqbal et al.· Processes· 0 citations
A hybrid framework combining MATLAB/Simulink-based modeling with Artificial Intelligence (AI) to enhance fault detection and classification in smart distribution grids and highlights the potential of integrating AI into modern power system protection schemes to achieve rapid, accurate, and cost-effective fault detectio...
Nizar Jabar Faqishafyee, Halbast Rashid Ismael, A. Hasan· Academic Journal of Internat...· 0 citations
Power distribution systems are becoming more complex and vulnerable day by day due to the increasing penetration of non-linear loads, renewable sources, and critical expansions of the overhead supply networks. Thus, the chances of distribution line failures have increased. On this occasion, effective fault detection ai...
Sukalyan Maji, D. Singh, E. Das et al.· Journal of Advanced Engineer...· 0 citations
The results indicate that phase-angle information provides supplementary and class dependent discriminative value, but does not consistently improve all fault classes, whereas conventional voltage and current measurements alone represent a simpler and more stable alternative, whereas phase-angle measurements may be inc...
Zeynep Bala Duranay, İsmail Anıl Avcı, Mohammed Bushra Mohammed et al.· Symmetry· 0 citations
To address the issue of ambiguous fault localization in multi-branch active distribution networks (ADN) caused by the weak characteristics of single-phase high impedance faults (HIF) and interference from distributed generation (DG), a fault section location method integrating multi-source transient features and topolo...
Zhe-Nang Zhang, Na Wu, Shu-Xian Fan· 2026 6th International Confe...· 0 citations
INTRODUCTION: High penetration of inverter-based distributed generators (IBDGs) changes power-flow patterns and fault transients in distribution networks, reducing the effectiveness of conventional outage identification. Under the adopted low-voltage ride-through control model, IBDG fault currents are limited to 1.2–1....
Ning Liu, Xiao-Peng Zhang, Xu-Dong Wang et al.· EAI Endorsed Transactions on...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.