This study develops an analytical model to characterize the progressive collapse resistance of a novel fully assembled concrete beam‐column substructure with bolted flange connections. The model, which idealizes the bolts as an equivalent continuous section to determine the rotational response and incorporates the hardening behavior arising from the elasto‐plastic deformation of the steel connectors, establishes the deformation compatibility relationship among the side column, steel connectors, and the prefabricated concrete beam. By introducing a bolt fracture criterion, the model enables precise identification of the mechanisms precipitating substructure failure. The predicted vertical load–displacement response and the evolution of internal forces at the critical sections show close agreement with the test results and finite element simulations. The validated model is subsequently employed to elucidate the mechanisms of internal force redistribution during both the flexural‐compressive arch action and catenary action stages, and to propose corresponding design recommendations. Finally, the effects of different parameters on the peak loads at various resistance stages are evaluated.
This study evaluates the structural behavior of hybrid bolted beam-to-beam connections for precast reinforced-concrete members through coupled testing and nonlinear simulation. Six full-scale assembled beams were tested in monotonic four-point bending, with three anchor-bolt diameters (16, 20, 24 mm) and two assembly c...
Wael Hameedi, I. Völgyi· Materials Structure· 0 citations
The mechanical response of bolted T‐stub components plays a key role in the nonlinear performance of steel joints. While existing analytical formulations provide accurate predictions for bending‐controlled collapse mechanisms, configurations connected to rigid supports and subjected to large displacements may exhibit a...
A. Francavilla, M. Latour, J. Demonceau et al.· ce/papers· 0 citations
Steel beam‐to‐column connections play a critical role in the overall seismic performance of steel structures, as they transfer the forces and show ductile behavior during lateral loading. Enhancing these connections through innovative retrofitting strategies can significantly improve structural resilience and reduce da...
Farzin Kazemi, Neda Asgarkhani, M. Fragiadakis et al.· ce/papers· 0 citations
Abstract This paper investigates the semirigid behavior of a precast beam–column connection with a column corbel and a beam dapped-end using a three-dimensional nonlinear finite element model and steel fiber–reinforced concrete in the force-transfer regions. The numerical model was calibrated and validated against expe...
M. N. Kataoka, Luiz Fernando Honorato Teodoro· Revista IBRACON de Estrutura...· 0 citations
Fiber-reinforced polymer (FRP) flanges are becoming increasingly adopted in piping systems owing to their corrosion resistance. However, current design standards for flanged joints are derived from those of metallic materials, neglecting the anisotropic behavior of composite laminates. This study develops a 3D anisotro...
Manal Amar, L. Boutahar, H. Chouiyakh· Journal of reinforced plasti...· 0 citations
This study presents a reformulated Gurson-type peridynamic model for the numerical simulation of ductile fracture in high-strength metallic materials. The approach is built within a non-ordinary state-based peridynamics framework and tightly couples the Gurson–Tvergaard–Needleman (GTN) model at the bond level. Specific...
Li-Wei Wu, Han Wang, Jian-Feng Zhou et al.· International journal of dam...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.