Sep 2026· IIUM Medical Journal Malaysia· 0 citations· 33 references
TL;DR
This study prioritizes technical viability over diagnostic accuracy relative to SPECT V/Q, supporting the feasibility of VP-Imaging for personalized RT.
Abstract
INTRODUCTION: Existing lung imaging lacks the dual assessment and spatial resolution needed for functional-avoidance radiotherapy. This proof-of-concept (PoC) feasibility study aimed to validate the technical feasibility of a novel voxel-level lung functional imaging technique based on ventilation-perfusion (VP) mapping and explore its preliminary utility in radiotherapy treatment planning.
Materials And Methods
We retrospectively analyzed 20 lung cancer patients with 4D-CT and PET/CT scans. Ventilation was calculated from 4D-CT deformable image registration, and perfusion from pre-processed PET images. High-function lung regions were defined as the top 40%. Three functional imaging modalities were generated: ventilation (V), perfusion (P), and VP imaging. The Dice Similarity Coefficient (DSC) and Bland-Altman plots evaluated agreement, and intensity-modulated radiation therapy (IMRT) plans were optimized for dosimetric comparison.
Results
The automated workflow took 45±15 minutes per patient, meeting clinical efficiency requirements. V-VP and P-VP showed moderate-to-good agreement in whole and low-function lungs (DSC up to 0.71; r up to 0.943) but poor agreement in high-function regions. VP-IMRT significantly reduced ipsilateral high-function lung V20Gy (81.03±56.03 to 61.14±64.44, p<0.001), with favourable dosimetric differences versus single-modality plans and no increased dose to organs at risk.
Conclusion
VP-Imaging effectively integrates ventilation and perfusion data, establishes a reproducible workflow, and shows preliminary dosimetric advantages. This study prioritizes technical viability over diagnostic accuracy relative to SPECT V/Q, supporting the feasibility of VP-Imaging for personalized RT.
Despite systematic perfusion increases early in treatment, its spatial stability remained stronger, supporting DECT perfusion as a more robust biomarker for longitudinal lung function assessment and for informing adaptive, functionally-guided RT in NSCLC.
Maksym Sharma, Christopher Tyerech, Daniel A. Alexander et al.· Physics in Medicine and Biol...· 0 citations
Abstract Background Pulmonary ventilation imaging has become an increasingly important component in thoracic radiotherapy, as it is applied to functional avoidance radiotherapy, where radiation doses are strategically minimized to preserve functional lung regions. Purpose We developed a framework that generates compute...
Y. Katsuta, T. Hoshino, Takaya Yamamoto et al.· Journal of Applied Clinical...· 0 citations
In PET/CT imaging, CT frequently accounts for more than 50% of the total radiation exposure, even when used solely for attenuation correction and anatomical localisation. This poses a major limitation for dose-sensitive populations, including pregnant women and paediatric patients. This study systematically evalu...
Georgios I. Angelis, Y. Gholami, K. Willowson et al.· EJNMMI Physics· 0 citations
PURPOSE
Recent studies indicate that lung function can change significantly during radiation therapy (RT) course. However, additional function imaging scans are not part of routine RT workflow, limiting the use of functional avoidance for adaptive therapy. To bridge this gap, we aimed to develop a deep learning model t...
Peixin Yu, Yao Pu, T. Xiong et al.· International Journal of Rad...· 0 citations
In patients who underwent thoracic PCCT, VNC images demonstrated agreement with TNC scans for lung volume and attenuation, and inspiratory depth, rather than reconstruction method, was the dominant source of attenuation variability.
Max L. Bodlien, S. Scharm, A. Hunkemöller et al.· Radiology· 1 citation
Four-dimensional computed tomography (4D-CT)-guided functional-avoidance radiotherapy reduces radiation pneumonitis, but the lack of patient selection criteria limits its adoption. This study aimed to identify clinical predictors of lung ventilation heterogeneity and determine which patients derive the greatest dos...
Guo-Zhong Deng, Yong-Quan Ying, Xiao-Mei Wang et al.· Frontiers in Oncology· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.