Aug 2026· Bioengineering· Vol 13· 0 citations· 38 references
Medicine
TL;DR
This study identified settings associated with improved quantitative metrics within the evaluated parameter space, with potential implications for quantitative imaging requiring clinical validation, and identified candidate optimised StarGuide/Q.Clear reconstruction parameters for 123I and 177Lu imaging.
Abstract
Accurate quantitative SPECT depends strongly on the reconstruction protocol, particularly for penalised-likelihood reconstruction algorithms, such as Q.Clear (BSREM). This study aimed to optimise Q.Clear reconstruction parameters for 123I and 177Lu imaging. SPECT images of a NEMA IEC PET Body phantom filled with 123I and 177Lu were acquired on a ring-shaped CZT camera and on a conventional Anger camera. The images were reconstructed using Q.Clear and OSEM and evaluated using quantitative image-quality metrics. Q.Clear was optimised for each radionuclide. The 123I dataset was reconstructed using different combinations of the regularisation parameters β and γ. The 177Lu dataset was reconstructed using literature-reported parameters, and the best-performing reconstruction was fine-tuned. The best-performing Q.Clear reconstructions were compared with corresponding OSEM reconstructions. Overall, increasing β reduced the recovery coefficients, background variability, and contrast recovery coefficients while increasing the signal-to-noise ratio. γ had no appreciable influence on the metrics within the investigated range. The candidate optimised StarGuide/Q.Clear reconstructions outperformed the standard Symbia/OSEM reconstructions in terms of activity recovery, whereas Symbia/OSEM produced lower image noise for most of the analysed VOIs. This study identified settings associated with improved quantitative metrics within the evaluated parameter space, with potential implications for quantitative imaging requiring clinical validation. Nevertheless, multiple reconstruction parameter combinations remain unexplored.
A practical commissioning workflow to optimize ¹⁷⁷Lu SPECT/CT imaging across different commercial scanner–reconstruction configurations is developed and a practical framework for local ¹⁷⁷Lu SPECT/CT optimization is provided.
L. Lampertico, G. Muti, C. Carbonini et al.· Advances in Radiotherapy &a...· 0 citations
Open-source BSREM showed task-, region, and count-dependent behavior, supporting task- and count-specific parameter selection before clinical application, and showed reduced left-putaminal uptake remained underestimated, and putaminal asymmetry moved further from their theoretical values.
Takuro Shiiba, Shingo Tanahashi, Kohei Takasu et al.· Physical and Engineering Sci...· 0 citations
Simulation-embedded reconstruction enabled integrated physical modeling within iterative reconstruction and improved the agreement with ideal reference images under controlled phantom-based conditions and supported the technical feasibility and basic validity of acquisition-consistent Monte Carlo-embedded reconstructio...
S. Shirakawa, Sayaka Fujita, H. Azuma et al.· Physica medica (Testo stampa...· 0 citations
A computationally efficient image-reconstruction pipeline for 3D balanced steady state free precession CINE fetal cardiac MRI that reduces radial streaking artifacts, increases effective temporal resolution, and improves diagnostic image quality compared with previous work is developed and evaluated.
M. Piek, J. Töger, E. Heiberg et al.· Magnetic Resonance in Medici...· 0 citations
MPR image quality is typically inferior to axial images and deteriorates further when derived from thicker axial slices, therefore, appropriate selection of the reconstruction kernel, pixel size and slice thickness are essential to maintain diagnostic image quality.
P. Monnin, A. Viry, F. Becce et al.· Journal of Applied Clinical...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.