Skip to content
Review Open access

Neurophysiological monitoring of cranial nerves III and VI in endoscopic skull base surgery: scoping review and comparative study

Sep 2026 · Frontiers in Oncology · Vol 16 · 0 citations · 44 references
Medicine

TL;DR

Multimodal IONM combining CbMEPs, tEMG, and fEMG is feasible and effective during EEA, and Modified 90° bent dual subdermal needle electrode appear to offer the most reliable and safe monitoring strategy for EOCN.

Abstract

Introduction Intraoperative neurophysiological monitoring (IONM) of extraocular cranial nerves (EOCN) during skull base surgery has expanded to reduce post-operative neurological deficits. However, multiple techniques exist, and comparative evidence supporting their routine use in endoscopic endonasal approaches (EEA) remains limited. The aim of the study is to evaluate the reliability, signal quality, and safety of different IONM techniques for CN III and VI during EEA, integrating a scoping literature review with a single surgeon’s clinical experience. Methods A scoping review identified studies reporting EOCN monitoring during EEA. In parallel, a retrospective analysis was conducted in patients undergoing extended EEA with multimodal IONM. Monitoring modalities included free-run electromyography (fEMG), triggered electromyography (tEMG), electrooculography (EOG), and corticobulbar motor evoked potentials (CbMEPs). Direct muscle recordings were obtained using hook-wire electrodes or modified 90°-bent subdermal needle electrodes, while indirect monitoring relied on EOG. Signal quality, reproducibility, feasibility, and procedure-related complications were assessed. Results Eleven studies involving 476 patients were included in the scoping review. In the clinical series, 51 patients underwent multimodal IONM. Direct EMG recordings provided stable and specific signals, whereas EOG showed a high artefactual component, limiting reliable nerve identification. CbMEPs yielded clear and reproducible responses in selected cases. Modified 90° bent dual subdermal needle electrode demonstrated superior signal quality and low impedance compared with hook-wire electrodes, which were associated with a higher rate of minor complications. Discussion Multimodal IONM combining CbMEPs, tEMG, and fEMG is feasible and effective during EEA. Modified 90° bent dual subdermal needle electrode appear to offer the most reliable and safe monitoring strategy for EOCN.

Read PDF

Similar papers

Review Open access Aug 2026

Advancements in intraoperative monitoring techniques in neurosurgical practice: a systematic review

Intraoperative monitoring (IOM) has become a vital component of contemporary neurosurgery, significantly reducing neurological deficits and improving surgical outcomes. This systematic review aims to evaluate recent advancements in IOM techniques in neurosurgical practice. A thorough literature search was conducted usi...

Hamid Sardari, Zahra Najafi, Elham Mohebi et al. · 0 citations
Review Open access Aug 2026

Impact of Intraoperative Neurophysiological Monitoring on Supratentorial Meningioma Surgery: A Systematic Review

Objectives: Our objective was to systematically evaluate the role of intraoperative neurophysiological monitoring (IONM) in supratentorial meningioma surgery, focusing on intraoperative changes, surgical decision-making, and postoperative neurological outcomes. Methods: A PRISMA-guided systematic review was conducted a...

Martina Offi, Renata Martinelli, Benedetta Burattini et al. · 0 citations
Review Open access Sep 2026

Intraoperative Neurophysiological Monitoring in Spina Bifida and Tethered Cord Surgeries: A Systematic Review of Clinical Outcomes

Spina bifida and tethered cord syndrome (TCS) are forms of spinal dysraphism requiring surgical intervention to prevent progressive neurological decline. Intraoperative neurophysiological monitoring (IONM) provides real-time feedback, allowing surgeons to minimize intraoperative injury during these procedures. This sys...

Vizmary J. Montes-Peña, Ana M. Ozguc, Pravallika Srusti et al. · 0 citations
Open access Aug 2026

Implementation of bedside and intraoperative neurophysiological monitoring in the diagnosis of functional neurological symptom disorder following spinal surgery: illustrative case

A 53-year-old woman developed profound lower extremity weakness and sensory loss after L3–5 decompression and fusion despite stable intraoperative neuromonitoring and imaging findings, which supported a multidisciplinary diagnosis of FND.

Sirisha Nouduri, A. Waheed, Hallie Triplett et al. · 0 citations
Review Open access Sep 2026

Noninvasive vagus nerve stimulation in otolaryngology: A scoping review and evidence map.

BACKGROUND Noninvasive vagus nerve stimulation (nVNS) may influence brainstem nuclei and ascending networks via vagal afferent pathways and has been investigated as an additional treatment for otolaryngological problems. Nonetheless, the evidence base is fragmented and methodologically diverse. OBJECTIVE To conduct a...

Xiang-Ming Meng, Ming-Jing Cai, Chao Hang · 0 citations
Sep 2026

Feasibility of F-Waves Monitoring Under General Anesthesia With Remimazolam: A Prospective Observational Study.

BACKGROUND F-waves are produced by the re-excitation of spinal anterior horn cells following distal electrical stimulation without being mediated through a conventional monosynaptic reflex pathway. F-waves can often be recorded even when voluntary motor output is limited and have been investigated as an adjunctive moda...

Sachiko Kawasaki, Hironobu Hayashi, T. Takatani et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.