Skip to content
Open access

Impact of Device Position and Aortic Valve Prolapse on Outcomes After Transcatheter VSD Closure.

Aug 2026 · JACC: Asia · Vol 6, pp. 2306-2316 · 1 citation · 29 references
Medicine

TL;DR

VSD closure using the MFO is safe and effective, including in patients with outlet-type VSD and AVP, and clamping of the aortic cusp may compromise long-term valve function.

Abstract

Background

Transcatheter closure of ventricular septal defect (VSD) is a promising alternative to surgery; however, outcomes in patients with coexisting aortic valve prolapse (AVP) remain limited.

Objectives

The authors aimed to evaluate outcomes and risk factors after VSD closure using the KONAR-MF Occluder (MFO) in a large Asian cohort with a high prevalence of AVP.

Methods

Between 2021 and 2024, consecutive patients undergoing transcatheter VSD closure at our institution using only the MFO were enrolled. Right coronary cusp (RCC) prolapse was quantified using the RCC prolapse index on transesophageal echocardiography. Device position relative to the aortic cusp was classified as nontouching, clamping, or holding. Risk factors for procedural failure and progression of aortic regurgitation (AR) were analyzed.

Results

Among 109 cases (13.8%, 15 of 109 doubly committed [Dc] type), 61.5% (67 of 109) had AVP. The procedural success rate was 94.5% (103 of 109; 95% CI: 88.4%-98.0%). Younger age, Dc VSD, aortic rim deficiency, and larger defect size were univariate correlates of failure, whereas RCC prolapse index was the only independent predictor in multivariate analysis (OR: 2.48; 95% CI: 1.06-5.83 per 10% increase; P = 0.037). During a median (IQR) follow-up of 14.3 (8.4-22.8) months, AR progression occurred in 7 (6.8%) patients. Device clamping of the aortic cusp was associated with AR progression (OR: 6.67; 95% CI: 1.10-58.1; P = 0.048).

Conclusions

VSD closure using the MFO is safe and effective, including in patients with outlet-type VSD and AVP. Significant RCC prolapse predicts procedural failure, and clamping of the aortic cusp may compromise long-term valve function.

Read PDF

Similar papers

Sep 2026

Valve Outcomes in Temporary Tricuspid Valve Detachment for Transatrial Ventricular Septal Defect Closure.

BackgroundIn ventricular septal defect (VSD) closure, accurately defining the margins of the VSD is essential for success. Transatrial tricuspid valve detachment (TVD) aims at improving visualization, which is often impaired by the tricuspid valve apparatus. However, this may affect operative time, atrioventricular (AV...

Supapong Watcharanat, Teerapong Tocharonechok · 0 citations
Sep 2026

Feasibility and Midterm Outcomes of Concomitant Aortic Valve Plasty in Contemporary HeartMate 3 Practice.

De novo aortic regurgitation (AR) remains a clinically significant complication of continuous-flow left ventricular assist device support, including the HeartMate 3 (HM3). Contemporary durability and safety data for concomitant aortic valve plasty (AVP) in HM3 recipients-particularly those bridged with temporary mechan...

K. Tonai, Kota Suzuki, N. Kitahata et al. · 0 citations
Open access Aug 2026

Transapical transcatheter mitral valve replacement with apical tethering system. Single-center mid-term results.

OBJECTIVES In high-risk patients, transcatheter mitral valve replacement (TMVR) is an alternative to surgery and transcatheter edge-to-edge repair (TEER). This study aims to evaluate the mid-term results of TMVR with the Tendyne System in a real-world population at a single center. METHODS Between November 2018 and D...

L. Besola, Cristina Di Franco, Federico Giorgi et al. · 0 citations
Open access Oct 2026

Transcatheter mitral valve implantation in complex anatomies: Outcomes after prior repair or aborted interventions.

BACKGROUND Patients with recurrent mitral valve disease after prior repair or persistent disease following an aborted edge-to-edge repair attempt face high risks with conventional surgery. The outcomes of transcatheter mitral valve implantation (TMVI) in these distinct cohorts remain unclear. METHODS This retrospecti...

C. Wahl, S. Voss, M. Erlebach et al. · 0 citations
Open access Sep 2026

Mid-term Outcomes after Aortic Valve Reimplantation with a Straight versus Valsalva Graft.

OBJECTIVES To compare mid-term hemodynamic performance and durability of valve-sparing aortic root reimplantation (VSRR) using a Straight versus Valsalva graft. METHODS From 1/1/2000-12/1/2023, 1,495 adults without endocarditis underwent VSRR at Cleveland Clinic, of whom 838 (56%) received a Straight graft and 657 (4...

Nika Samadzadeh Tabrizi, Brad F. Rosinski, Holliann Umana et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.