Skip to content
Open access

Sensitivity-Guided BESS Siting and Sizing with Uncertainty-Aware Scheduling in Renewable-Rich Distribution Networks

Sep 2026 · Symmetry · 1 citation

Abstract

High penetrations of wind and photovoltaic generation create simultaneous challenges for battery energy storage system (BESS) planning in distribution networks, including differences in nodal regulation value, power-energy configuration, and day-ahead operation under forecast uncertainty. This study develops a sequential planning-to-operation workflow comprising candidate-bus generation, siting and sizing within the candidate set, and finite-scenario day-ahead scheduling for a fixed configuration. First, nodal net-injection sensitivities, Jacobian-assisted pre-screening, and deterministic topology/support safeguards are used to generate the main candidate set, and alternating-current (AC) finite-difference refinement is performed only for the sensitivity-led fast set; in the IEEE-33 system, this refinement reduces the number of AC power-flow calls from 65 for full-node analysis to 17. Next, Sensitivity-Guided Envelope-Based Nonanticipative Adjustable Recourse Optimal Power Flow (SG-ENAR-OPF) is solved separately for each bus in the main candidate set; the BESS location and power/energy capacities are jointly determined subject to the P-Q LinDistFlow model, BESS duration constraints, a shared affine response, and finite-scenario constraints. The full-node audit serves only as an independent paper-level validation benchmark and is not part of the deployable workflow. After the configuration is fixed, interval forecasts for load, photovoltaic (PV) output, and wind-turbine (WT) output at // are used to construct 25 static load-renewable disturbance points and seven temporal stress paths, over which a shared finite-scenario day-ahead policy is optimized. The IEEE-33 MAIN case selects Bus 30, with BESS capacities of approximately 10.66 MW/10.66 MWh. Using scaled public time-series data, the final policy is replayed over 46 consecutive 24 h execution windows, comprising 1104 h actual trajectories; under the 0.002 MW/MWh storage-engineering criterion, all 46/46 windows pass storage engineering validation, and energy continuity is maintained across all 45/45 interday boundaries. Further nonlinear AC post-validation converges at all 1104/1104 operating points, of which 1058/1104 satisfy the complete voltage and branch-capacity constraints. Supplementary results for IEEE-69 show that the workflow can be executed on a second radial test feeder. However, the conclusions are strictly limited to the tested feeders, finite scenarios, scaled public-data settings, and stated engineering tolerances and do not constitute a formal guarantee over a continuous uncertainty domain or of general cross-system applicability.

Read PDF

Similar papers

Open access Sep 2026

Flexibility-Oriented Co-Planning of Renewable Generation, Network Reinforcement, Demand Response, and Battery Storage in Active Distribution Networks

Planning network reinforcement and flexibility as separate tasks obscures when they substitute for, or complement, one another. We formulate a scenario-hour mixed-integer linear program (MILP) that selects photovoltaic and wind capacity, battery power and energy, energy-neutral demand shifting, photovoltaic-inverter re...

He-Ran Kang, Jie Chen, Yong-Hui Sun et al. · 1 citation
Open access Oct 2026

Uncertainty-aware bilevel energy storage planning for active distribution networks: A fixed-topology DistFlow-based MISOCP framework with voltage-security assessment

Historical renewable-load variability, voltage-security risk, and investment-operation coupling can materially change the assessed value of distribution-level energy storage. This study develops an uncertainty-aware bilevel energy storage system (ESS) planning framework in which the upper level selects a discrete sitin...

Zhen-Hua Miao, Zi-Yan Li, Yong-Jie Wang · 0 citations
Open access Sep 2026

Topology Aware Mixed Discrete Optimization for Optimal Siting and Sizing of Distribution-Static Synchronous Compensators in Electric Vehicle Charging Stations Connected Microgrid Considering Reactive Power Tariffs

Optimal allocation of Distribution Static Synchronous Compensators (D-STATCOMs) is critical for enhancing modern distribution grid performance. However, integrating load and generation volatility alongside technoeconomic objectives yields a highly complex, non-linear, mixed-integer optimization problem. Existing method...

S. Dash · 0 citations
Open access Sep 2026

Multi-Objective Jellyfish Search Algorithm for Two-Level Stochastic Planning and Demand-Side Management of Renewable-Integrated Microgrids

The optimal placement and power injection of photovoltaic (PV), wind, and battery energy storage system (BESS) units are critical for reliable microgrid operation under renewable-generation uncertainty. This study proposes a two-level planning-and-operation framework for a grid-connected microgrid. At the planning stag...

Vijithra Nedunchezhian, Muthukumar Kandasamy, Renugadevi Thangavel et al. · 0 citations
Open access Oct 2026

MO-MODBO-MCS-Based Stochastic Multi-Objective Planning of Distributed Generators and EV Charging Stations in Radial Distribution Networks Under Voltage-Dependent Loads

The incorporation of clean distributed generators (DGs) to fast-charging EV hubs presents significant operational challenges to modern distribution grids. The intermittent nature of solar and wind generation, combined with the uncertainty of EV charging demand, makes the optimal planning of these resources particular...

Mratyunjay Singh, Bindeshwar Singh, S. Singh · 0 citations
Open access Sep 2026

Two-stage stochastic optimization for planning and operation of multiple types of mobile energy resources in distribution networks

High penetrations of wind and photovoltaic (PV) generation increase temporal and scenario-dependent source–load variability in distribution networks, complicating the planning and operation of mobile energy resources. This paper proposes a multi-scenario-driven planning–operation co-optimization method that incorporate...

Zhu Tong, Hai Zeng, Xia-Han Zhou et al. · 0 citations