Uncertainty-aware bilevel energy storage planning for active distribution networks: A fixed-topology DistFlow-based MISOCP framework with voltage-security assessment
Oct 2026· PLoS ONE· Vol 21, pp. e0353192 - e0353192· 0 citations· 44 references
Medicine
Abstract
Historical renewable-load variability, voltage-security risk, and investment-operation coupling can materially change the assessed value of distribution-level energy storage. This study develops an uncertainty-aware bilevel energy storage system (ESS) planning framework in which the upper level selects a discrete siting-sizing-duration plan and the lower level solves a fixed-topology, multi-scenario mixed-integer second-order cone program (MISOCP) in which the network physics are represented by a DistFlow-SOCP formulation. An ESS-aware topology robustness check is further introduced to examine whether ESS-induced topology changes affect the planning conclusions obtained under the common-topology comparison. Complete daily load, photovoltaic, and wind observations from Denmark in 2016 and 2017 are represented as joint 72-dimensional trajectories. Input-risk-stratified historical-day reduction is examined for K = 3, 5, 10, and 20, with K = 10 used for the principal 33-bus study and K = 20 used as a higher-fidelity scenario-set check. Exhaustive evaluation of 211 alternatives identifies a 1.00 MW/ 2.00 MWh ESS at bus 24. Under K10 and the baseline fixed topology, the proposed design reduces daily TOTEX from 73,151.02 to 51,826.24 CNY/day (29.2%) relative to No ESS, raises the minimum voltage from 0.94138 to 0.95405 p.u., and reduces cumulative undervoltage exposure from 0.013528 to 0.001740 p.u.·h. Cross-year and seven-day chronological tests retain the economic and security pattern. On the released 240-bus feeder, the reference design improves voltage exposure, loading, and losses at a small incremental economic cost. These results show that historical tail conditions, common-topology attribution, and physical security metrics are important for auditable ESS planning.
Renewable power plants with co-located battery energy storage systems (BESSs) coordinate forecast-deviation control, renewable-surplus management, electricity-price arbitrage, and ancillary-service commitments through the shared power and energy capability of the battery. This study develops a layered framework for sce...
Jing Hu, Yan-Hao Wang, Na-Na Li et al.· Energies· 0 citations
In regional power grids with multiple high-voltage direct-current (HVDC) infeeds, renewable-generation variability, variations in HVDC power transfers, and network constraints are strongly coupled, while planning solutions derived from DC power-flow models may not ensure AC operational feasibility. To address these iss...
Ying Wang, Zhen-Yu He, Xu Ling et al.· Frontiers in Energy Research· 0 citations
High rooftop photovoltaic (PV) penetration causes reverse-power-flow stress, voltage rise, and PV curtailment to vary across low-voltage transformer service areas. Fixed-location flexibility cannot respond effectively when these stresses migrate over time. This paper develops a coordinated planning and operation fram...
Shu-Can Zhou, Min-Jia Zheng, Xin-Yi Huang et al.· Frontiers in Energy Research· 0 citations
This paper proposes a multi-objective distributed energy storage planning method that couples distribution-level electricity market simulation to improve the coordination between storage investment, market participation, and distribution network operation. The method incorporates technical–market-based candidate-bus sc...
Da-Cheng Wang, Ming-Hui Duan, Zhe Wang et al.· Energies· 0 citations
The proliferation of hyperscale data centers, together with tightening carbon-neutrality targets, exposes the limits of the line-frequency transformer (LFT) that still dominates data-center power distribution and motivates a fresh look at the conversion and dispatch layer. This paper develops an energy management frame...
Xiang Liu, Wan-Ling Luo, Xin-Gang Yang et al.· Scientific Reports· 0 citations
The integration of photovoltaic (PV) systems, energy storage systems (ESSs), and electric vehicles (EVs) in residential communities introduces challenges from renewable-generation uncertainty, load variability, and battery degradation. This paper proposes a stochastic mixed-integer linear programming (MILP) framework f...
Adool Kruekaew, A. Namvong, Manussawee Nokkaew et al.· Energies· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.