Skip to content

Year-round evaluation of pilot-scale Anaerobic/Oxic/Anoxic system treating municipal wastewater under low temperature: performance and microbial response.

Sep 2026 · Bioresource Technology · Vol 464, pp. 135815 · 0 citations · 47 references
Medicine

Abstract

Although the Anaerobic/Oxic/Anoxic (AOA) process has been widely investigated, comprehensive research on its performance under low temperature remains limited. In this study, a pilot-scale AOA system with treating capacity of 84.2 m3/d was developed to treat municipal wastewater over 395 days. Despite fluctuations in water temperature (10.4-31.2℃) and influent BOD5/TN (1.1-7.7), the system achieved average effluent total nitrogen (TN) and total phosphorus (TP) concentrations of 4.9 mg/L and 0.3 mg/L without chemical addition. Notably, the anoxic zone contributed up to 74.9 % of TN removal. Extending anoxic hydraulic retention time to 11 h mitigated the adverse impacts of low temperature on endogenous denitrification rate. With intracellular carbon storage efficiency exceeding 78.7 %, carbon consumption was minimized through the integrated control of dissolved oxygen and residual NH4+-N. Consequently, the AOA system delivered effluent TN and TP of 6.5 mg/L and 0.2 mg/L under low-temperature (14.1 ± 1.6℃) and low BOD5/TN (3.6 ± 1.0) conditions. Microbial and metabolic analyses revealed adaptive response to seasonal cooling and carbon limitation, with stable glycogen-accumulating organisms (GAOs) and denitrifiers (0.9 % and 9.0 %), accompanied by increased abundances of genes involved in intracellular carbon and denitrification pathways. Compared with an Anaerobic/Anoxic/Oxic (AAO) system operated at wastewater treatment plant receiving identical influent, the AOA system yielded decreased effluent TN by 2.3 mg/L, external carbon expenditure by $46.4 per 10,000 m3 wastewater and aeration volume fraction by 21.9 %. This study provided insights into the practical application of the AOA process in regions characterized by low temperature and carbon limitation.

View source

Similar papers

Oct 2026

Enhancing Nitrogen Removal from Low C/N Municipal Wastewater via Redistributing Hydraulic Retention Time in a Pilot-Scale Anaerobic/Aerobic/Anoxic Process.

Advanced nitrogen removal from low-carbon municipal wastewater is often constrained by insufficient organic carbon for complete denitrification. In this study, a pilot-scale Anaerobic/Aerobic/Anoxic (AOA) reactor with a capacity of 57.6 m3/d was operated for 175 days to assess nitrogen removal supported by stored intra...

Wei-Liang Pan, Chuan-Song Xia, Shan-Shan Li et al. · 0 citations
Open access Nov 2026

A high-rate anaerobic/oxic membrane bioreactor for phosphorus removal and carbon capture from municipal wastewater: Operational limits and energy-recovery potential via sidestream anaerobic digestion.

Integrating enhanced biological phosphorus removal (EBPR) with high-rate activated sludge treatment is an attractive strategy for achieving simultaneous phosphorus removal and carbon recovery; however, its stability at short sludge retention times (SRT) under low hydraulic retention time (HRT) conditions remains poorly...

Yi-Zhuo Sun, Wei-Zhe Xia, Min Ye et al. · 0 citations
Sep 2026

Enhancement of nitrogen and phosphorus removal by coupling pyrite-based autotrophic denitrification with an electro-enhanced A2/O process.

Conventional anaerobic-anoxic-oxic (A2/O) processes often exhibit low nutrient removal efficiency and high operational costs when treating carbon-limited wastewater from highway service areas. In this study, a pyrite-based autotrophic denitrification process coupled with an electro-enhanced A2/O system (PE-A2/O) was de...

Zhi-Ming Zhang, Bo-Bo Yuan, Nuerla Ailijiang et al. · 0 citations
Oct 2026

Enhancing low-temperature nitrogen removal in municipal wastewater through sludge fermentation products and hydraulic retention time optimization: polyhydroxyalkanoate-associated endogenous carbon metabolism.

Low-temperature (15 °C) municipal wastewater treatment is constrained by electron-donor deficiency and slowed microbial kinetics. Within an integrated floc-biofilm sequencing batch reactor under anaerobic-aerobic-anoxic mode, this study investigated the combined effects of sludge fermentation products (SFP) addition an...

Rui Wang, Jin-Jin Liu, Xi-Yao Li et al. · 0 citations
Open access Oct 2026

Dual-parameter aeration control improves post-anoxic denitrification by limiting aerobic depletion of biomass-associated carbon pools.

Aeration control in anaerobic-oxic-anoxic systems must sustain nitrification while preserving carbon for post-anoxic denitrification. The effectiveness of combining rear-zone low aeration with ammonium feedback remains insufficiently resolved. A 90 m3/d pilot system was operated for 245 d under conventional aeration (C...

Lisan Yao, Bai-Shuo Shao, Ling-Yan Gu et al. · 0 citations
Oct 2026

Enhanced nitrogen removal from low C/N municipal wastewater at ambient temperatures through integration of partial denitrification/anammox and partial nitrification/anammox in step-feed continuous-flow pure-biofilm anoxic/oxic/anoxic system.

The limited enrichment and retention of anaerobic ammonium-oxidizing bacteria (AnAOB), coupled with inadequate nitrite supply, remain major obstacles to implementing anammox-based processes in mainstream wastewater treatment. Hence, in this research, a step-feed continuous-flow pure-biofilm anoxic/oxic/anoxic (AOA) pro...

Jian-Tao Ji, Hui-Ru Li, Fei-Yue Hu et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.