Skip to content

A-384 Development of a sensitive, quantitative C-peptide immunoassay on a dry-printed carbon nanotube electrochemical sensor

Oct 2026 · Clinical Chemistry · Vol 72 · 0 citations

TL;DR

The C-peptide immunoassay built on CNT-based electrochemical sensors is capable of highly sensitive and robust quantification of C-peptide from patient urine samples and has the potential to be the core technology of a point-of-care diagnostic, which would improve patient outcomes and reduce health care costs.

Abstract

A key regulator of glucose homeostasis is insulin secretion from pancreatic beta-cells. C-peptide, a byproduct of insulin formation, is produced in equal amounts with insulin, and can be used as a biomarker for beta-cell function. Urinary C-peptide concentration has generated increasing interest as a reliable, non-invasive method for assessing insulin production. Here we present a point-of-care diagnostic concept for simple, reliable, and quantifiable C-peptide detection from urine samples on a carbon nanotube (CNT)-based electrochemical biosensor. This simplified diagnostic workflow would allow for end-user (patient) testing without requiring invasive blood draws, ultimately promoting continuity of care and decreasing health-care costs. We developed an electrochemical immunosensor on CNTs and tested the sensitivity of two immunoassay formats, competitive and sandwich. Urinary C-peptide levels from subjects without diabetes range from 40 to 150 ng/mL, where people living with type 1 diabetes have lower than normal levels and people with type 2 diabetes have higher levels. To ensure identification of clinically relevant low and high C-peptide levels, calibrators spanning 0 to 1000 ng/mL were used to assess the analytical performance. For testing in urine, five pooled urine sample standards were acquired from the BioPersMed Cohort (Medical University of Graz, Austria), and C-peptide was quantified for each pool using the ADVIA Centaur® system (4.6 – 127.6 ng/mL). C-peptide was detected on the CNT biosensor using a TMB-HRP redox reporter system, benchtop potentiostat (PalmSens, EMSTAT4 MUX), and an optimized chronoamperometry method. A custom python-based electrochemical analytical pipeline was developed in parallel to ensure that assay precision, sensitivity, and signal/noise ratios were integrated readouts of overall quantification of C-peptide during the assay development. Amperometric measurement results identified the sandwich assay format to be more robust across the relevant clinical range and more sensitive for clinically low sample concentrations (<40 ng/mL) than the competitive assay. Analytical electrochemical analyses demonstrated numerous valid and reproducible methods for quantifying current signals from chronoamperograms. These methods ranged from simple (e.g., a set window of time was used for all experiments) to complex (steady-current plateau identification based on a sliding-scale identifying the smallest standard deviation within subsequent current recordings). To date, steady-current identification appears to be a robust quantification method with improved signal/noise ratios seen across relevant clinical concentrations. The C-peptide immunoassay built on CNT-based electrochemical sensors is capable of highly sensitive and robust quantification of C-peptide from patient urine samples. Integrating analytical quantification methods into the assay development process allowed for improved assay precision and increased assay throughput. This assay has the potential to be the core technology of a point-of-care diagnostic, which would improve patient outcomes and reduce health care costs.

View source

Similar papers

Sep 2026

Affinity peptide-based microfluidic electrochemical system for ultrasensitive detection of amyloid-β peptides.

In serum samples, the μF-APEC system showed strong agreement with conventional enzyme-linked immunosorbent assay measurements and clearly distinguished AD patients from healthy individuals, demonstrating its potential for the early screening of AD.

Ang-Yang Shang, Zhi-Qi Zhang, Jing-Yuan Zhao et al. · 0 citations
Sep 2026

A Microfluidic Electrochemical Immunosensor for Point‐of‐Care Testing of Cystatin C in Human Serum

Chronic kidney disease (CKD) is a progressive disorder characterized by structural and functional alterations in the kidneys arising from various etiologies. Cystatin C (Cys C) is regarded as a superior endogenous biomarker because it is less affected by confounding factors such as age and gender. In this work, an...

Hao-Miao He, Xiu-Qiang Dai, Jing Wei et al. · 0 citations
Sep 2026

Sample-to-Answer Serum Diagnostics System-on-Chip.

Integrating multiple bioanalytical functions onto a single chip for point-of-care protein detection remains challenging. Here, we introduce a biological detection system-on-chip (BDSoC) that merges the purification capabilities of microfluidic chips with the detection sensitivity of carbon nanotube (CNT) field-effect t...

Zi-Jun Zhao, Lu Wan, Ke-Min Wang et al. · 0 citations
Aug 2026

Peptide-based digital ELISA with single-molecule arrays for ultrasensitive and specific endotoxin detection in clinical plasma and pharmaceutical products.

A peptide-based digital enzyme-linked immunosorbent assay (dELISA) that integrates two high-affinity, phage-displayed peptides into a single-molecule array platform, enabling highly sensitive and specific endotoxin detection without the use of antibodies is reported.

Jun-Rong Li, Kun Cao, He-Qing Yang et al. · 0 citations
Oct 2026

A-383 Electrochemical Detection of IL-6 on Canatu functionalized Carbon Nanotube Dry-Printed Electrodes: Preliminary data on linear response across a low-nanogram range

Interleukin-6 (IL-6) is a clinically important inflammatory cytokine, and rapid quantification can support early decision-making in a range of acute and chronic conditions. Electrochemical biosensing is a promising route for point-of-care (POC) inflammation assessment due to low sample volume requirements, portab...

Jane Besong-Ndika, A. Soliman, N. Joon et al. · 0 citations
#protein folding Oct 2026

All-printed immunosensing microchip for fast and sensitive detection of urinary soluble Fms-like tyrosine kinase-1 in preeclampsia diagnosis.

We present an all-printed immunosensing microchip that integrates hydrophilic-hydrophobic patterning, covalent antibody immobilization, and photonic bandgap engineering into a single, scalable manufacturing platform for high-sensitivity protein detection. By precisely matching the microchip's photonic bandgap (centered...

M. Zeng, Xiao-Long Xu, Xu-Yun Liu et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.