Skip to content
Open access

Quantification of image quality and partial volume effect along the axial field-of-view of uMI Panorama GS PET/CT system for multiple radionuclides.

Jul 2026 · EJNMMI Physics · 0 citations
Medicine

TL;DR

The assessment demonstrated comparable image qualities for 18F, 64Cu, 68Ga, 89Zr, 124I, and 90Y, while 90Y showed a similar CRC but a higher BV and a higher lung residual error, attributable to its low positron branching ratio.

Abstract

Purpose

The comprehensive knowledge of how the distinct physical decay characteristics of each radionuclide shape their image quality performance is essential for tailoring acquisition protocols and ensuring optimal clinical applications. Understanding the spatial dependence of the contrast recovery coefficient (CRC) is a prerequisite for robust quantitative image analyses and accurate clinical interpretations, since the partial volume effect (PVE) and the count rate vary along the axial field of view (AFOV). Image quality assessments with various radionuclides were performed on the uMI Panorama GS PET/CT system, with the CRC profile across its extended AFOV also evaluated.

Methods

Following the NEMA NU 2-2018 standard, the image quality was assessed using the NEMA IEC (NEC) Body Phantom with 18F, 64Cu, 68Ga, 89Zr, 124I, and 90Y. The CRC, the background variability (BV), and the lung residual error were measured to quantify the image quality. CRCs were sequentially measured at four axial offsets: 1/2, 1/4, 1/8, and 1/16 of the AFOV. The impact of the radionuclide-specific PSF (point spread function) modeling on the CRC was evaluated by comparing PET images reconstructed with and without PSF modeling.

Results

The assessment demonstrated comparable image qualities for 18F, 64Cu, 68Ga, 89Zr, 124I, while 90Y showed a similar CRC but a higher BV and a higher lung residual error, attributable to its low positron branching ratio. The BV and lung residual error increased with increasing axial distance from the AFOV center, whereas CRCs for larger spheres remained stable across AFOV positions; small-sphere CRC measurements exhibited increased dispersion toward the periphery due to reduced count statistics. The PSF modeling significantly improved CRCs for 68Ga and 124I, consistent with their long positron ranges.

Conclusions

All investigated radionuclides were effectively imaged on the uMI Panorama GS PET/CT system. The AFOV uniformity was quantitatively evaluated based on CRC measurements obtained at multiple positions along the AFOV.

Read PDF

Similar papers

Open access Sep 2026

Effects of count rate performance on image quality in an LAFOV PET/CT system

This study investigated the relationship between body size, administered activity, and image quality (IQ) using two patient-like phantoms representing normal and obese body profiles, and demonstrated the count rate capabilities up to and beyond the saturation limit.

Nanna Overbeck, Zuzanna Czeluśniak, Søren Holm et al. · 0 citations
Sep 2026

EARL-based quantitative evaluation of administered activity reduction for [68Ga]Ga-DOTATOC PET/CT on a 32-cm axial FOV digital BGO system: Phantom analysis and retrospective list-mode clinical assessment.

PURPOSE The increased sensitivity of long-axial field-of-view (FOV) digital PET/CT systems enables potential reductions in administered activity and/or acquisition time with respect to standard-field-of-view systems and established clinical protocols, while preserving quantitative performance. This study aimed to evalu...

A. Piai, B. Bordigoni, L. Antunovic et al. · 0 citations
Open access Sep 2026

Multi-parameter imaging of dual-layer detector spectral CT in improving the imaging quality of gastrocolic trunk of henle (GTH)

To investigate the clinical application value of multi-parameter imaging with dual-layer detector spectral CT (DLCT) for GTH visualization. A total of 61 patients who underwent abdominal portal venous phase-enhanced SLCT were retrospectively enrolled. The raw image data were reconstructed into 120 kVp conventional imag...

Xiao-Ou He, Nai-Wen Mu, Jia-Cun Li et al. · 0 citations
#edge computing Open access Aug 2026

Task‐based evaluation of axial and multiplanar reconstructions in computed tomography: A volumetric analysis of spatial resolution, noise, and detectability

MPR image quality is typically inferior to axial images and deteriorates further when derived from thicker axial slices, therefore, appropriate selection of the reconstruction kernel, pixel size and slice thickness are essential to maintain diagnostic image quality.

P. Monnin, A. Viry, F. Becce et al. · 0 citations
Sep 2026

High-dose-rate prostate brachytherapy imaging optimization: A motorized sagittal three-dimensional ultrasound acquisition system.

The motorized attachment for SR3D acquisition reduced image variability and improved image quality, and may encourage broader use of sagittal reconstruction in HDR-BT, potentially improving patient outcomes.

David Contella, Chandima Edirisinghe, Kevin Barker et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.