Dual-energy CT with metal artifact reduction for post-EVAR CTA surveillance: a prospective study with image quality analysis.

Jul 2026 · Abdominal Radiology · 0 citations · 24 references
Medicine

TL;DR

The integration of DECT-VMIs with the iMAR algorithm appears to improve image quality in post-EVAR CTA by effectively reducing stent-related metal artifacts while enhancing vascular and soft-tissue visualization.

View source

Similar papers

Open access Sep 2026

Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging

Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retr...

Andreea I. Nica, C. Booz, G. Bucolo et al. · 0 citations
Sep 2026

Photon-counting detector CT with virtual monoenergetic imaging and iterative metal artifact reduction for spinal fusion implants: optimal keV and combined benefits.

For spinal implants, PCD-CT offers effective approaches for metal artifact and 120 keV is preferred and the combination of iMAR and 120 keV introduce new artifacts and requires careful consideration.

Xin-Ying Huang, Zai-Zhu Zhang, Yong An et al. · 0 citations
Open access Sep 2026

A wide-detector CT protocol for one-stop cardio-cerebrovascular angiography: a technical feasibility study comparing an integrated protocol with conventional two-scan approach

Objective To evaluate the clinical utility of a wide-detector CT protocol with variable helical pitch (vHP) for one-stop cardiovascular and cerebrovascular CT angiography. Methods This prospective randomized study enrolled 61 patients (25 in the Group A and 36 in the Group B) with suspected cardiovascular and cerebrova...

Jie-Zhi Yan, Fei-Yan Wang, Shui-Xian Huang et al. · 0 citations
#edge computing Open access Aug 2026

Task‐based evaluation of axial and multiplanar reconstructions in computed tomography: A volumetric analysis of spatial resolution, noise, and detectability

MPR image quality is typically inferior to axial images and deteriorates further when derived from thicker axial slices, therefore, appropriate selection of the reconstruction kernel, pixel size and slice thickness are essential to maintain diagnostic image quality.

P. Monnin, A. Viry, F. Becce et al. · 0 citations
Sep 2026

Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment.

Background Use of virtual noncontrast (VNC) images from photon-counting CT (PCCT) may reduce radiation dose and support quantitative lung analysis by obviating the need for separate true noncontrast (TNC) acquisitions. Their accuracy for lung densitometry, however, has not been systematically assessed. Purpose To evalu...

Max L. Bodlien, S. Scharm, A. Hunkemöller et al. · 1 citation
Open access Aug 2026

Plaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT

The findings support implementing standardized protocols with automatic dual-range reconstructions to enable efficient, individualized carotid plaque assessment in clinical practice and support implementing standardized protocols with automatic dual-range reconstructions for keV selection based on plaque composition.

Mirela Kostadinova, Lea B. Uebelacker, Tommaso D'Angelo et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.