Aug 2026· International Journal of Electrical Power & Energy Systems· Vol 181, pp. 112169· 0 citations· 69 references
Computer ScienceEngineering
TL;DR
A standardization-oriented framework that turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions is proposed.
Abstract
Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting. Protection task, physical scope, measurements, timing, targets, preprocessing, and validation often vary jointly and remain incompletely specified. This paper proposes a standardization-oriented framework that treats evaluation design as part of the scientific contribution. It defines seven required study dimensions: protection objective, physical scope, observability, timing and decision windows, targets and sample validity, validation protocol, and evaluation outputs. The framework is instantiated in a bounded case study on the public PROTECT-90 electromagnetic-transient benchmark, comprising 9022 simulated episodes from a 90 kV double-line topology, for onset-conditioned fault classification and localization. Under centralized sensing, simulation-metadata-aligned 20 ms windows, and episode-grouped validation, a multi-layer perceptron (MLP) achieved a five-fold mean macro-averaged F1 score of 0.991 +/- 0.001 for classification and a localization mean absolute error of 10.20 +/- 0.25% of line length (mean +/- std across episode-grouped folds). Extending the decision horizon to 50 ms preserved this task-dependent performance asymmetry, while reduced observability approximately doubled the MLP localization error but had little effect on classification. A synchronized two-ended conventional locator outperformed the learning locators under its richer clean information set, and measurement degradation showed that clean predictive performance did not determine robustness. The framework turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions.
The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements across a diverse set of topologies and voltage levels.
Georg Kordowich, Jonathan Loebel, Julian Oelhaf et al.· 2 citations· ⚡1
A software-based database-generation and smart-learning framework that converts 22 candidate risk factors into six normalized severity levels and then maps the simultaneous system state to low-, medium-, and high-level protection decisions, supporting early fault detection, maintenance planning, and resilience improvem...
A. Elasyri, Nazım İmal, M. Fidan· Energies· 0 citations
This study explores the use of machine learning algorithms to classify security levels of contingencies in power systems into safe, moderate or severe classes, and highlights machine learning as a scalable and powerful alternative to traditional contingency analysis.
(English) The rapid decarbonization of power systems and the large-scale integration of inverter-based resources (IBRs), high-voltage direct current (HVDC) links, and power-electronics-based technologies are profoundly transforming the dynamic behavior of modern electric grids. These changes introduce new stability cha...
The results should be interpreted as a reproducible bench validation of the acceptance protocol and deployment profiles on a bench ICS/HIL dataset, not as proof of industrial effectiveness for a particular process control object.
Evgeniy V. Ilyin, Irina G. Sidorkina· Computational nanotechnology· 0 citations
The results indicate that phase-angle information provides supplementary and class dependent discriminative value, but does not consistently improve all fault classes, whereas conventional voltage and current measurements alone represent a simpler and more stable alternative, whereas phase-angle measurements may be inc...
Zeynep Bala Duranay, İsmail Anıl Avcı, Mohammed Bushra Mohammed et al.· Symmetry· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.