Oct 2026· Energies· Vol 19, pp. 4796· 0 citations· 22 references
Abstract
The purpose of this study is to compare the energy performance characteristics of two small modular reactor (SMR) technologies, the AP300 and the BWRX-300, under conditions of simultaneous electricity and heat production. Mathematical models of both systems were developed, covering the steam–water cycle, the turbine and the heat recovery system. The analysis was carried out for a heat output range of 50–500 MWt, under identical heat utilisation conditions. The gross and net electrical power, in-house plant consumption, electrical, thermal and total efficiency, unit steam consumption and the cogeneration index were assessed. The symmetric percentage difference (PD) was used for a quantitative comparison of the characteristics. The results showed that the BWRX-300 has lower in-house plant consumption, whilst the AP300 has lower unit steam consumption for electricity generation. For this indicator, the PD value ranges from 15.77% to 31.08%, with an average of 22.21%. Furthermore, it was shown that the impact of reactor technology on cogeneration characteristics depends on the parameter under analysis. The largest differences relate to parameters associated with the conversion of heat into electricity, whilst characteristics related to heat production show a higher degree of consistency.
Small modular reactors (SMRs), including the NuScale design, are primarily intended for electricity production. In the context of the ongoing energy transition in Poland, aimed at reducing the use of fossil fuels, SMRs may serve as a low-emission alternative to conventional power generation sources. In order to make be...
R. Laskowski, A. Smyk, N. Uzunow et al.· IOP Conference Series: Earth...· 0 citations
This study aims to analyze the performance of the rooftop Solar Power Plant (PLTS) with a capacity of 87.4 kWp as the energy supply of the H₂ Plant at PT PLN Nusantara Power UP Pacitan. The research method used is a descriptive quantitative method with an approach to analyze the performance of the photovoltaic system b...
Dharma Dwi Prastya, Irna Tri Yuniahastuti, Ina Sunaryantiningsih· Nucleus Journal· 0 citations
This study evaluates the thermal performance of the cooling tower at PT. Geo Dipa Energi Unit Patuha, a 60 MW single-flash geothermal power plant, using cooling-water temperature range, approach, and effectiveness, and examines their statistical relationships with condenser pressure and turbine output power. Operationa...
Fitri Wijayanti, Muhammad Ridho Kurnia, Paulus Sukusno· Jurnal Mekanik Terapan· 0 citations
This work focuses on low-power autonomous power plants that use low-grade heat sources to convert thermal energy into mechanical and electrical energy. The task addressed relates to the insufficient efficiency of existing technical solutions for autonomous power supply to remote consumers using low-grade heat sources w...
A. Alkina, A. Mekhtiyev, Y. Neshina et al.· Eastern-European Journal of...· 0 citations
This research is based on the biomass power plant at PT. Permata Hijau Indonesia. This study investigates the flow of steam, the pressure of steam and electrical energy consumed by the fan, control panel and feed pump. This is where the biomass power plant is observed for its greatest operation condition. This is when...
W. Huang, B. Ismail, M. Irwanto et al.· 2026 2nd International Confe...· 0 citations