Skip to content
Open access

AN LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY BIOANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS QUANTIFICATION OF GLECAPREVIR AND PIBRENTASVIR IN HUMAN PLASMA

Oct 2026 · Asian Journal of Pharmaceutical and Clinical Research · pp. 157-164 · 0 citations

TL;DR

The validated LC–MS/MS method was selective, sensitive, accurate, precise, and robust for the simultaneous quantification of GPV and PBV in human plasma, making it suitable for pharmacokinetic, bioavailability, bioequivalence, and therapeutic drug monitoring studies.

Abstract

Objective: This study aimed to develop and validate a rapid, sensitive, and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalytical method for the simultaneous quantification of glecaprevir (GPV) and pibrentasvir (PBV) in human plasma. Methods: Chromatographic separation was achieved on a Phenomenex C18 column (50×4.6 mm, 5 μm) maintained at 35°C using an isocratic mobile phase consisting of 0.1% formic acid and acetonitrile (ACN) (15:85, v/v). Quantification was performed using positive electrospray ionization in multiple reaction monitoring (ESI–MRM) mode with daclatasvir (DCV) as the internal standard. Plasma samples were processed by protein precipitation with ACN, evaporated under nitrogen, and reconstituted with 200 μL of mobile phase before LC-MS/MS analysis. The method was validated according to the US Food and Drug Administration (US-FDA) bioanalytical method validation guideline for selectivity, carry-over, linearity, accuracy, precision, matrix effect, extraction recovery, dilution integrity, and stability. Results: The method demonstrated excellent linearity over concentration ranges of 29.85–1194 ng/mL for GPV and 5.5–220 ng/mL for PBV using weighted (1/x²) linear regression, with regression equations of y=0.002073x+0.001400 (r²=0.99984) for GPV and y=0.016048x+0.002243 (r²=0.99969) for PBV. No endogenous interference or significant carry-over was observed. Extraction recovery ranged from 95.14% to 102.52% for GPV and 96.97% to 98.03% for PBV, with acceptable precision. Matrix effect was negligible, dilution integrity satisfied the acceptance criteria, and intra- and inter-day accuracy and precision met US-FDA requirements. Stability studies confirmed that both analytes remained stable under short-term, long-term, freeze–thaw, bench-top, autosampler, wet extract, and dry extract storage conditions. Conclusion: The validated LC–MS/MS method was selective, sensitive, accurate, precise, and robust for the simultaneous quantification of GPV and PBV in human plasma. The method exhibited satisfactory extraction recovery, negligible matrix effect and carry-over, acceptable dilution integrity, and excellent stability, making it suitable for pharmacokinetic, bioavailability, bioequivalence, and therapeutic drug monitoring studies.

Read PDF

Similar papers

Open access Oct 2026

A Rapid Liquid Chromatography–Tandem Mass Spectrometry Bioanalytical Method For Quantification Of Gepirone In Rat Plasma Using Lurasidone As An Internal Standard: Method Development, Validation And Pharmacokinetic Application

Gepirone is an azapirone antidepressant that acts primarily through partial agonism of serotonin 5-HT1A receptors and has gained renewed attention following its approval for major depressive disorder. This study designed to create a simple and reliable Liquid Chromatography–Tandem Mass Spectrometry procedure for determ...

Talluri Sarada Mrinalini, R. Thagele, N. Kilaru et al. · 0 citations
Open access Sep 2026

An Lc-Ms/Ms Method Development and Validation for the Quantification of Lurbinectedin in Biological Matrices; Application to Kinetic Study in Rabbits

The findings regarding accuracy, specificity, sensitivity, matrix effect, recovery and stability findings of Lurbinectedin in plasma samples for the established method highlight its significance in bioequivalence and pharmacokinetic studies.

P. Sankar, Naresh Panigrahi · 0 citations
Open access Oct 2026

Development and Validation of Liquid Chromatography–Tandem Mass Spectrometry Method for Quantification of Lazertinib in Plasma Samples and Pharmacokinetic Study in Rabbits

The aim of the present study was to establish a precise, linear, and specific liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC–ESI–MS/MS) technique for the quantitative estimation of lazertinib in plasma of rabbits. Analyte separation was accomplished on a Phenomenex C18 (50 × 4.6 mm, 2.1...

Balakrishna Attuluri, M. Rudrapal, Venkateswararao B et al. · 0 citations
Aug 2026

Sustainable UHPLC-MS/MS assay for ultra-sensitive simultaneous quantification of amoxicillin and flucloxacillin with application to a bioequivalence study.

The developed UHPLC-MS/MS method was successfully applied in a bioequivalence study involving 33 healthy volunteers following oral administration of a single 5 mL dose of Flucamox® 250 mg, enabling comprehensive pharmacokinetic evaluation while promoting sustainable and resource-efficient analytical practices.

M. Hegazy, Ashraf S. Ibrahim, M. Kenawy et al. · 0 citations
Open access Oct 2026

A robust liquid chromatography–tandem mass spectrometry method for accurate quantification of omeprazole in human plasma: Integration of International Council for Harmonisation guidelines for pharmacokinetic application

A simple, rapid, and reliable bioanalytical method based on protein precipitation coupled with LC-MS/MS was developed and validated for the quantification of omeprazole in human plasma. The method employs protein precipitation with acetonitrile for sample preparation, offering a fast and efficient extraction proces...

Choukri El Khabbaz, E. M. Eddarai, Oumaima Ouaouda et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.