Dosimetric study of split-arc technique based on personalized collimator optimization in VMAT for multiple brain metastases.

Oct 2026 · Applied Radiation and Isotopes · Vol 239, pp. 113011 · 0 citations · 30 references
Medicine

TL;DR

Balancing dosimetric quality and efficiency, the 6-split arc (6sA) strategy is recommended as the preferred protocol for MBM.

Abstract

Purpose

To evaluate the multiple split-arc technique in mitigating the "island blocking effect (IBE)" during volumetric modulated arc therapy (VMAT) for multiple brain metastases (MBM) and identify the optimal clinical protocol.

Methods

A retrospective analysis of 20 MBM patients (2-5 targets) was performed. Four VMAT plans were generated per patient: a control group (2A, conventional dual arcs) and three experimental groups (4sA, 6sA, 8sA) where arcs were split with personalized collimator optimization based on beam's eye view (BEV). Dosimetric parameters for planning target volumes (PTV), normal brain tissue (NBT), organs at risk (OARs), and delivery metrics (MU, complexity metric [CM], control point mean jaw area [AJaw, mean], control point mean jaw-X/Y width [WJaw-X/Y, mean]) were compared.

Results

All strategies met prescription requirements with no significant differences in CI or HI (P > 0.05). Experimental groups showed significant improvements in GI, NBT mean dose (Dmean), V12Gy, MU, CM, AJaw, mean and WJaw-X/Y, mean (P < 0.05), with improvements correlating with the number of sub-arcs.Specifically, 6sA and 8sA groups significantly reduced NBT's Dmean and V12Gy (P < 0.01), and OAR exposure (P < 0.05). The 8sA group achieved the best performance, with GI, MU, CM, and WJaw-X, mean reduced by 12.05%, 14.43%, 10.80%, and 27.52%, respectively, while WJaw-Y, mean increased by 24.04% compared to the 2A group (P < 0.001). However, no statistically significant differences were found between the 6sA and 8sA groups regarding MU, CM, or most OAR sparing (P > 0.05).

Conclusion

The split-arc technique with collimator optimization effectively mitigates IBE and reduces NBT dose. Balancing dosimetric quality and efficiency, the 6-split arc (6sA) strategy is recommended as the preferred protocol for MBM.

View source

Similar papers

Evaluation of the dosimetric leaf gap for VMAT-SBRT in small target volumes

This study aims to tune the measured DLG for the lung and prostate using the VMAT-SBRT technique by using electronic portal imaging (EPID), and recommends tuning from the gamma passing rate per arc to avoid dose washing out.

Grit Phianpholdeesakun · 0 citations
Open access Sep 2026

Dosimetric comparison of organs at risk exposure in multicatheter high-dose-rate interstitial brachytherapy vs. VMAT-based APBI for real patient treatment plans

Purpose To dosimetrically compare multicatheter interstitial high-dose-rate brachytherapy (MIBT) with two volumetric modulated arc therapy (VMAT) techniques, i.e., continuous (cVMAT) and tangential (tVMAT), for accelerated partial breast irradiation (APBI), specifically focusing on organs at risk (OARs) exposure. Mater...

A. Krzystyniak, R. Maksim, Kamil Szczecina et al. · 0 citations
Open access Oct 2026

Cohort-specific dosimetric and delivery tradeoffs for proton dynamic arc vs. IMPT for breast and chest wall irradiation.

PURPOSE To compare proton dynamic arc therapy (DynamicArc) with conventional intensity-modulated proton therapy (IMPT) for breast/chest wall irradiation across diverse clinical anatomies. METHODS Forty patients were analyzed (10/cohort): tissue expanders, permanent implants, no reconstruction, and bilateral disease....

Kristen McConnell, R. Rohe, Valeriane Mcneill et al. · 0 citations
Open access Sep 2026

Forward-Planned Multisegmented Technique in Resource-Limited Settings: A Feasible Dosimetric Upgrade for 3D-CRT in Locally Advanced Nasopharyngeal Carcinoma

In resource-limited settings, intensity-modulated radiotherapy (IMRT) is often unavailable, forcing reliance on three-dimensional conformal radiotherapy (3D-CRT) for advanced nasopharyngeal carcinoma (NPC). This limits curative potential due to challenges in sparing organs-at-risk (OARs) while covering complex target v...

AS Badiane, M. Dieng, Lef Edimo et al. · 0 citations
Sep 2026

Comprehensive and Comparative Dosimetric Characterization of VMAT and IMRT in Brain Cancer Treatment Planning: Target Coverage, OAR Sparing, Monitor Units, Dose Distribution, Low-Dose Volumes, and Delivery Efficiency

VMAT and IMRT were comparable in terms of target coverage and normal tissue protection, but VMAT needed fewer monitor units and had a significantly lower V20 with numerically lower V5 and V10 although these were not statistically significant.

Abbood Abbas Abbood · 0 citations