Aug 2026· Energies· Vol 19, pp. 3943· 0 citations· 31 references
TL;DR
This paper develops a coordinated restoration architecture for multi-area feeders containing PV, battery energy storage, and charging stations using public 33-node and 123-node feeders together with synthetic 240-node and 850-node stress networks.
Abstract
Extreme weather couples spatially correlated component damage with photovoltaic (PV) derating, changing electric-vehicle (EV) demand, repair delay, and time-varying network topology. This paper develops a coordinated restoration architecture for multi-area feeders containing PV, battery energy storage, and charging stations. Its weather-facing layer constructs joint outage-risk, renewable-error, charging-demand, and voltage-vulnerability descriptors. Those descriptors parameterize a two-stage mixed-integer second-order-cone program with a finite-support optimal-transport ambiguity set that remains well defined for discontinuous mixed-integer recourse. Regional actor–critic agents propose five-minute corrections around the hourly robust schedule; constrained projection, non-linear AC power-flow screening, emergency fallback, and margin-tightened re-optimization retain the authority to accept or reject each proposal. The evaluation uses public 33-node and 123-node feeders together with synthetic 240-node and 850-node stress networks. A pre-fit manifest allocates 240 records to training, 80 to validation, and 320 to final testing, while aggregate operational outcomes cover 50 random streams. Within this controlled benchmark, accepted schedules restore 93.6% of critical-load energy (SD 2.1 percentage points), serve 96.7% of total demand (SD 1.8 percentage points), retain 82–86% of EV service across hazard classes, and reduce the modeled 24 h objective by 25.8% relative to deterministic dispatch. The full pipeline records two to four candidate-stage voltage-limit events by hazard, and 4.9% of candidates undergo tightened re-optimization before accepted schedules reach zero reported AC voltage-limit violations. Between-method comparisons are descriptive and unpaired; the larger synthetic cases are structural stress tests rather than feeder-transfer tests.
Aggregated demand response is a constrained sequential-control problem because electric vehicles, distributed batteries, thermostatically controlled loads, flexible industrial demand, and behind-the-meter photovoltaic systems are heterogeneous, uncertain, and connected to voltage- and thermal-limited feeders. We formul...
Xuan Liu, Lei An, Yan Lu et al.· Scientific Reports· 0 citations
Offshore engineering microgrids integrate renewable generation, energy storage, and large marine test loads. Frequent start-stop transients of test loads, strong wind/PV fluctuations, and saline–humid conditions accelerate equipment aging and threaten power quality, while conventional dispatch neglects battery degradat...
Xiang-Yu Gu, Nan Hu, Lei Zhang et al.· Energies· 0 citations
Single-bus planning of rural photovoltaic (PV)–wind–battery microgrids can overstate tail reliability because it omits feeder constraints and may use future stress information unavailable to a causal controller. We develop a progressive framework that compares 13 literature-derived planning families under a common budg...
Restoring a bulk power system after a blackout involves black start, network reconfiguration and load restoration, usually optimized in sequence; renewable stations used as early sources add an output uncertainty that the schedule must anticipate. This paper formulates the three stages jointly for systems with photovol...
Renewable-rich distribution dispatch must coordinate grid import, storage, curtailment, and controllable demand while accounting for feeder-security risk. This study evaluates a calibrated soft network-security-aware model predictive control (MPC) framework for radial feeders. A branch-flow and voltage proxy is fitted...
High rooftop photovoltaic (PV) penetration causes reverse-power-flow stress, voltage rise, and PV curtailment to vary across low-voltage transformer service areas. Fixed-location flexibility cannot respond effectively when these stresses migrate over time. This paper develops a coordinated planning and operation fram...
Shu-Can Zhou, Min-Jia Zheng, Xin-Yi Huang et al.· Frontiers in Energy Research· 0 citations