Skip to content
Open access

Effects of Bolt-Tightening Torque and Rubber Interlayer Thickness on the Slip Resistance of Nylon Coupler–GFRP Circular-Tube Joints

Oct 2026 · Buildings · Vol 16, pp. 4037 · 0 citations · 28 references

Abstract

To characterize the slip-resistant behavior of nylon-coupler joints in prefabricated GFRP circular-tube crossing frames, a two-factor experimental investigation was conducted considering bolt-tightening torque and rubber interlayer thickness. Four interface configurations were examined: no interlayer and rubber interlayers with thicknesses of 1.0, 1.5, and 2.0 mm. Six bolt-tightening torque levels of 5, 7, 9, 11, 13, and 15 N·m were considered. Three replicate tests were conducted for each parameter combination, yielding 72 test records. The relative axial displacement measured by D1, the transverse displacement recorded at D2, and load-transfer-beam strain were monitored to characterize the loading response. Because most load–relative displacement curves did not reach a distinct post-peak descending branch, the maximum recorded load within each recorded test window (Fmax) was used only as a comparative index and was supplemented by the loads at fixed D1 relative axial displacements of 5, 10, and 15 mm. The maximum transverse displacement recorded at D2 remained below 3 mm for all specimens, indicating that the transverse response at the monitored point remained limited during the tests. When the bolt-tightening torque increased from 5 to 15 N·m, the mean Fmax values of joints with no interlayer and with 1.0, 1.5, and 2.0 mm interlayers increased by 133.0%, 200.1%, 167.3%, and 171.7%, respectively. Two-way analysis of variance indicated that bolt-tightening torque, interlayer thickness, and their interaction were all statistically significant (p < 0.001), accounting for 56.35%, 34.34%, and 5.41% of the total sum of squares, respectively. The 1.0 mm interlayer consistently produced the highest mean Fmax at each torque level. The fitted slope of its Fmax–torque relationship was 0.542 kN/(N·m), approximately 2.43 times that of joints without an interlayer. The results suggest that an interlayer of appropriate thickness can improve interfacial conformity and the effectiveness of frictional load transfer, whereas increasing interlayer thickness may introduce greater compressive and shear deformation. Within the specific rubber material, joint configuration, bolt-tightening torque range of 5–15 N·m, and nominally symmetric short-term monotonic loading conditions examined in this study, the 1.0 mm interlayer exhibited the best overall performance among the tested configurations.

Read PDF

Similar papers

Open access Nov 2026

Behaviour of welded lean duplex stainless steel T-stub components under varying loading rates

This study presents the first systematic investigation of the strain rate dependent response of welded lean duplex stainless steel T-stub components through an integrated experimental and numerical modelling programme. Twenty-four T-stub specimens incorporating M16 and M20 fully threaded A4 – 70 and DX109 bolts were te...

W. Li, M. Cabrera, M. Theofanous et al. · 0 citations
Open access 2026

Mechanical Performance of Beam-Column Joints in Glued Laminated Timber Structures: A Design Evaluation and Idealized Envelope Approach

Beam–column connections play a critical role in load transfer and lateral stability in Glued Laminated Timber (GLT) frame buildings. Assessing their design performance, however, requires both a check against design standards and a measure of stiffness and connection ductility, which normally depends on continuous load–...

Thinh D. T., V. T, Son N. H. · 0 citations
Open access Sep 2026

Three-Point Bending and Cohesive Zone Analysis of Resistance-Welded Carbon-Fiber-Reinforced Polycarbonate to Aluminum 7075 Single-Lap Joints

Abstract Resistance-welded thermoplastic composite-metal hybrid joints may be useful for temporary or secondary aerospace repair concepts, but their small-coupon response is difficult to interpret because bending, peel, sliding and welding-induced residual stresses occur simultaneously. This paper presents an adapted t...

Marcin Praski, P. Kowalczyk, Radosław Szumowski et al. · 0 citations
Open access Sep 2026

Shear Behaviour of Polyurethane Screw-Glued and Serrated Steel Plate Flange-to-Web Joints in Ribbed CLT Panels

The present study investigates the shear behaviour of screw-glued and mechanical flange-to-web connections intended for cross-laminated timber (CLT) ribbed panels, with the aim of improving composite behaviour and enhancing the structural performance of long-span timber floor and roof systems. Fifteen CLT-glue laminate...

Elza Briuka, Ernests Kiops, D. Serdjuks et al. · 0 citations
Conference Open access Oct 2026

Numerical simulation study on plastic buckling of thin-walled aluminum alloy tubing under cyclic bending

The 6061-T6 thin-walled tube material is prone to cyclic plastic buckling failure during rotational straightening and reciprocating bending service. In actual rotational straightening production lines and long-term reciprocating bending service, the tube bears repeated alternating positive/negative bending curvature lo...

Ye Huo, Li-Cheng Ren, Yan-Peng Xu et al. · 0 citations