Hardware reliability priorities may depend on the decision time scale, which a single importance ranking may obscure. A solar-powered unmanned aircraft system (UAS-A) for field-information support is assessed using a 21-event static fault tree, 17 minimal cut sets, an analytical solution, and Python (version 3.9.6) and MATLAB (R2025b) Monte Carlo implementations. The model targets hardware-induced loss of control under specified functional-loss criteria; software, human factors, weather and bird strikes remain outside its scope. With the compiled rate inputs and independent failures, the mean time to first failure (MTTF) is 43,038.8 h and the top-event probability at 24 h is 9.3701 × 10−5. Halving each component rate in turn gives a Spearman correlation of rS = 0.0546 between lifetime and finite-horizon sensitivity rankings throughout the sampled 1–48 h reference range. It rises to 0.939 at 8760 h and 0.996 near 40,000 h. First-order paths dominate short-horizon sensitivity under independence, while accumulated photovoltaic (PV) failures influence longer horizons. PV common-cause scenarios can elevate short-horizon PV priority. These horizons describe model evaluation; flight endurance requires an energy assessment. The workflow supports prioritization conditional on the functional topology, rate inputs and dependence model; emergency-return benefits additionally depend on detection and recovery sequences.
Power-system alternatives involve coupled trade-offs among fuel economy, thrust, response, and mass, requiring evaluation from a mission-level perspective rather than through isolated technical indicators. However, existing methods provide limited traceability from subsystem parameters to mission effectiveness under un...
This study combines short-horizon prediction of exact-zero-power onset with field-informed evaluation of a maximum-power-point controller multiplier with a corrected analysis using Shapley additive explanations to provide a practical framework linking interpretable condition monitoring with field-informed power optimiz...
Sedat Dalkiran, C. Niebuhr· Processes· 0 citations
The global transition toward renewable energy has significantly accelerated the deployment of wind turbine fleets, particularly in remote onshore and harsh offshore environments. As the scale of these fleets expands, operations and maintenance costs have emerged as a dominant factor influencing the levelized cost of en...
David Collins· Fundamental Scientific Repor...· 0 citations
Artificial Intelligence (AI) data centers are emerging as converter-dominated, parameter-rich electrical systems whose dynamic response depends on fast workload-driven demand variations, tightly regulated data-hall converters, and coordinated on-site sources. Assessing such systems by repeatedly solving nonlinear time-...
Arnav Bagga, Saskia A. Putri, Abhishek Banerjee et al.· 0 citations
Model predictive control (MPC) of microgrid battery energy storage is shaped by two design choices that are almost always refined together: the temporal resolution of the schedule and the accuracy of the net-load forecasts it uses. This paper decouples these two factors. We show that the real-time regulating burden on...
Single-bus planning of rural photovoltaic (PV)–wind–battery microgrids can overstate tail reliability because it omits feeder constraints and may use future stress information unavailable to a causal controller. We develop a progressive framework that compares 13 literature-derived planning families under a common budg...
Jun-Di Ni· IEEE Access· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.