Skip to content

Accuracy and safety of individualized 3D-printed guides for L4 pedicle screw placement: An in vitro comparison with the free-hand technique

Aug 2026 · Proceedings of the Institution of mechanical engineers. Part H, journal of engineering in medicine · Vol 240, pp. 921 - 934 · 0 citations · 39 references
Medicine

TL;DR

It is suggested that individualized 3D-printed guides may improve the reproduction of planned L4 pedicle screw trajectories in printed bone models and be interpreted as exploratory in vitro geometric evidence.

Abstract

Pedicle screw fixation is widely utilized for lumbar stabilization, but deviation from the planned pedicle corridor may result in cortical breach and neurovascular injury. Individualized 3D-printed guides may help transfer preoperative planning to screw insertion. However, their guiding performance and measurement reliability still require quantitative validation in controlled L4 models. This in vitro comparative study evaluated the accuracy, safety, and measurement reliability of guide-assisted L4 pedicle screw placement. Five L4 vertebrae were selected from a public spine CT dataset to design and print individualized guides and corresponding bone models. Bilateral screw placement was performed in both the guide-assisted and free-hand groups. Postoperative CT scans were registered to preoperative planning models to assess entry point deviation, 3D angular error, axial and sagittal plane angular errors, and Gertzbein-Robbins (GR) grading. Registration quality and the reliability of repeated measurements were also evaluated. The guide-assisted group showed lower positional and angular errors than the free-hand group across all quantitative metrics, and this pattern was consistent across the five paired specimens. A higher strict Grade A rate was observed in the guide-assisted group, although both groups achieved a 100% clinically acceptable rate (Grade A + B). These findings suggest that individualized 3D-printed guides may improve the reproduction of planned L4 pedicle screw trajectories in printed bone models. Because only five independent L4 specimens were included and PLA models cannot reproduce bone density or tactile feedback needed for free-hand placement, the between-group comparison should be interpreted as exploratory in vitro geometric evidence. The workflow provides a quantitative framework for the in vitro evaluation of guide-assisted screw placement.

View source

Similar papers

Open access Aug 2026

3D-printed patient-specific guides improve screw accuracy in upper cervical spine surgery: a comparative study

Objective To evaluate the feasibility and clinical efficacy of patient-specific 3D-printed guide plates for pedicle screw placement in the upper cervical spine, compared with the conventional free-hand technique. Methods A retrospective analysis was conducted on 39 patients who underwent upper cervical spine surgery be...

Guo-Qi Niu, Ya-Long Guo, Gong Zhou et al. · 0 citations
Review Sep 2026

3D-Printed Guides, Navigation, and Robotic Assistance in Spinal Instrumentation: A Network Meta-Analysis of Pedicle Screw Accuracy and Clinical Outcomes.

BACKGROUND Accurate pedicle screw placement is essential to prevent neurovascular injury, revision surgery, and excess healthcare costs. While navigation and robotic systems enhance accuracy over freehand or fluoroscopic techniques, they remain limited by high cost and patient radiation exposure. Three-dimensional prin...

Shehab Eid, Navid Ghaderi, R. Koucheki et al. · 0 citations
Open access Aug 2026

Accuracy of pedicle screw fixation under O-arm and navigation guidance in thoracolumbar spine surgery

Background: Accurate pedicle screw placement is critical for successful thoracolumbar spine fixation. Misplacement can lead to complications such as neurological injury, vascular damage, and the need for revision surgeries. The use of 3D intraoperative imaging and navigation systems, such as the O-arm and Stealth syste...

R. Gupta, Swaroop Patel, A. K. Jha et al. · 0 citations
Sep 2026

Accuracy of Guide-Free, Mixed Reality-Assisted Patient Specific Implant Fixation for Maxillary Repositioning: A Cohort Study.

OBJECTIVE To develop a mixed reality (MR)-assisted, guide-free workflow for patient-specific implant (PSI)-based maxillary fixation and evaluate its positioning equivalence and procedural efficiency relative to conventional guide-assisted PSI fixation. METHODS In this non-randomized cohort study, 28 patients undergoi...

Li-Wei Huang, Hao-Ning Li, Zhaokun Zhu et al. · 0 citations
Open access Sep 2026

The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.

STUDY DESIGN Retrospective comparative cohort study. INTRODUCTION Accurate pedicle screw placement is critical for spinal stability and for preventing neurological or vascular injury. This study compared screw-placement accuracy and safety between robot-assisted and navigation-guided pedicle screw implantation and ex...

Ali Mulhem, Lennart Schreiweis, H. Krenzlin et al. · 0 citations
Sep 2026

Impact of Level of Guidance on the Accuracy of Static Computer-Assisted Implant Surgery (s-CAIS): An In Vitro Study.

BACKGROUND Accurate implant placement is essential for predictable functional and esthetic outcomes. Although static computer-assisted implant surgery (s-CAIS) is more accurate than freehand placement, the effects of increasing guidance within partially guided workflows and on adjacent-implant relationships remain uncl...

Eric C. MacFadden, Christopher Sobczak, A. Guentsch · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.