Skip to content

Accuracy of Guide-Free, Mixed Reality-Assisted Patient Specific Implant Fixation for Maxillary Repositioning: A Cohort Study.

Sep 2026 · E -journal of dentistry · Vol 176, pp. 107013 · 0 citations · 42 references
Medicine

TL;DR

MR-assisted, guide-free PSI fixation showed positioning outcomes statistically equivalent to guide-assisted fixation within the prespecified margins and was associated with greater procedural efficiency.

Abstract

Objective

To develop a mixed reality (MR)-assisted, guide-free workflow for patient-specific implant (PSI)-based maxillary fixation and evaluate its positioning equivalence and procedural efficiency relative to conventional guide-assisted PSI fixation.

Methods

In this non-randomized cohort study, 28 patients undergoing Le Fort I osteotomy independently selected their preferred workflow after receiving detailed information on both approaches and were categorized according to the workflow received. MR navigation guided osteotomy lines and screw-hole positioning in the MR-assisted group, whereas conventional surgical guides were used in the guide-assisted group. Equivalence was assessed using two one-sided tests (TOST), with margins of ±0.5 mm for translational and ±1.0° for rotational outcomes.

Results

All 90% confidence intervals (CIs) for between-group differences in translational and rotational positioning errors were entirely within the prespecified equivalence margins, supporting statistical equivalence within these bounds. Small directional offsets were observed for A-X (mean difference, -0.206 mm), UL6-Y (0.168 mm; 90% CI, 0.070-0.267 mm), and yaw (0.159°; 90% CI, 0.017-0.302°), although all remained within the equivalence margins. Preoperative preparation time and mean Le Fort I segment time were reduced in the MR-assisted group, which also required fewer intraoperative adjustments (2.29 ± 1.49 vs. 4.29 ± 1.20; P = 0.0006).

Conclusion

MR-assisted, guide-free PSI fixation showed positioning outcomes statistically equivalent to guide-assisted fixation within the prespecified margins and was associated with greater procedural efficiency. CLINICAL RELEVANCE MR-assisted, guide-free PSI fixation may reduce reliance on surgical guides while maintaining between-workflow positioning differences within prespecified equivalence bounds.

View source

Similar papers

Open access Sep 2026

Impact of Level of Guidance on the Accuracy of Static Computer-Assisted Implant Surgery (s-CAIS): An In Vitro Study.

Accuracy varied by guidance level and greater plan-to-implant accuracy was not accompanied by improved inter-implant parallelism, indicating that these outcomes should be evaluated separately.

Eric C. MacFadden, Chris M. Sobczak, A. Guentsch · 0 citations
Open access Oct 2026

Accuracy of maxillary positioning in semi-guided orthognathic surgery using 3D-printed cutting guides and bending plates: A retrospective study.

Preliminary findings suggest that semi-guided orthognathic surgery can transfer the VSP with deviations within the range observed for the conventional splint-based workflow, and may represent a clinically promising alternative to conventional splint-based workflows and fully patient-specific implant-based approaches in...

M. Beyer, Oliver V. Waldvogel, Lea Alig et al. · 0 citations
Oct 2026

Surgical Efficiency, Learning Dynamics, and Positional Accuracy of Freehand Immediate Implant Placement Under Standardized Digital Planning: An In Vitro Study.

PURPOSE To characterize surgical efficiency and within-operator learning dynamics during freehand immediate post-extraction implant placement performed under standardized, prosthetically driven digital planning, and to describe the positional accuracy achieved across operators of differing experience in a 3D-printed ph...

C. Lorenzi, A. Pinto, A. Alrmali et al. · 0 citations
Open access Oct 2026

Accuracy of augmented reality-assisted versus template-guided implant surgery: an in-vitro comparative study.

This in-vitro comparative study aimed to examine the accuracy of augmented reality-assisted implant placement compared to the conventional drilling templates. Twenty maxillary bone models were used to perform 80 implant placements using two different methods. Every bone model received four implants: two were placed usi...

F. A. Bosshard, T. Di Giovanni, L. Schaufelberger et al. · 0 citations
Open access Oct 2026

Comparative accuracy of dynamic navigation versus static surgical guides for dental implant placement: an in vitro assessment of free-end and non-free-end configurations

To compare the accuracy of dynamic navigation and static surgical guides for dental implant placement, with emphasis on free-end versus non-free-end configurations. An in vitro study was conducted using stereolithographic models of partially edentulous maxillary and mandibular arches. Sixty implant sites were virtually...

Chang-De Sui, Fatanah Mohamad Suhaimi, J. Roffie et al. · 0 citations
Sep 2026

OPTIMISING ACCURACY OF COMPUTER-ASSISTED IMPLANT SURGERY USING NOVEL DRILLING KEY DESIGN: SIMULATION-BASED STUDY.

BACKGROUND Accurate implant positioning remains the goal of guided surgery for improving surgical outcomes and minimizing complications. The aim is to compare the accuracy of standard versus novel drilling key in static-dynamic computer assisted implant surgery across D2 and D3 bone densities relative to a zero-deviati...

Thaysan Kaing, S. Arunjaroensuk, X. Yeo et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.