Oct 2026· Frontiers in Neurology· Vol 17· 0 citations· 26 references
Medicine
TL;DR
The findings question its reliability as a stand-alone tool for serial monitoring of dynamic ICP changes in treated neurocritical care patients and therefore should not be interpreted as a direct substitute for invasive ICP or as a stand-alone measure of short-term ICP change.
Abstract
Introduction Monitoring intracranial pressure (ICP) is a key component in the management of patients with intracranial hemorrhage. Transorbital ultrasound (toUS)- based measurement of the optic nerve sheath diameter (ONSD) - has been proposed as a non-invasive surrogate for ICP assessment. However, substantial variability in measurement techniques and cut-off values has raised concerns regarding its reliability. This study aimed to evaluate the association between repeatedly measured ONSD and invasively measured ICP in patients with intracranial hemorrhage and to assess the ability of ONSD to reflect changes in ICP over time. Methods In this prospective longitudinal study ONSD was measured daily using ultrasound at 3- and 6 mm posterior to the optic disc and compared with simultaneously recorded invasive ICP measurements. A total of 55 patients with intracranial hemorrhage were included, contributing repeated measurements over a mean of 5.47 ± 2.27 days. Results Overall, the association between ICP and ONSD was weak. In the prespecified primary analysis, ICP was not associated with bilateral mean irONSD at 3 mm (β = 0.004 mm per mmHg, 95% CI − 0.003 to 0.011; p = 0.169; marginal R2 = 0.3%). At 6 mm, a small but statistically significant relationship was detectable at bilateral ICP mean values for outer-reflection ONSD [β = 0.010, 95% CI (0.002–0.019), p = 0.016; marginal r2 = 1.3%]. Conclusion ICP explains less than 2% of the variance in ONSD in this treated cohort with predominantly controlled ICP. These findings question its reliability as a stand-alone tool for serial monitoring of dynamic ICP changes in treated neurocritical care patients and therefore should not be interpreted as a direct substitute for invasive ICP or as a stand-alone measure of short-term ICP change.
BACKGROUND AND OBJECTIVES
Elevated intracranial pressure (ICP) is a critical and potentially life-threatening complication of pediatric encephalitis. Early detection is essential for improved outcomes. This study assessed the diagnostic utility of optic nerve sheath diameter (ONSD) ultrasound for identifying elevated I...
Duy Ngoc Le Huynh, T. Tran, Thuc Thanh Tran et al.· Annals of Indian Academy of...· 0 citations
It was concluded that ONSD measurement is a reliable method for identifying patients with elevated ICP and Cerebral computed tomography and clinical presentation are not sufficient standards for assessing ICP.
C. Scorza, F. Scorza, J. Finsterer· Revista da Associação Médica...· 0 citations
This study validates the clinical utility of ultrasound-derived ONSD indices in optimizing ICP assessment before craniotomy and proves they are reliable non-invasive biomarkers for predicting elevated ICP in neurocritical patients.
Guang-Zhao Li, Xiao-Wang Niu, Kai-Peng Zhang et al.· Frontiers in Neurology· 0 citations
ONSD measured by bedside ultrasonography correlates inversely with neurological status and demonstrates responsiveness to therapeutic intervention in adult TBI, supporting its potential role as a practical, noninvasive adjunct to clinical neurological assessment.
Mohamed Elnokaly, Mohamed Gamal, S. Issa et al.· Egyptian Journal of Neurosur...· 1 citation
Abstract Background: Detection of intracranial involvement in acute hypertension traditionally relies on fundoscopy, a method with limited applicability at the bedside. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) has emerged as a rapid, non-invasive alternative. Objective: To synthesize evide...
João Victor de Oliveira Ramos, Marcelo Tavares· ABC Imagem Cardiovascular· 0 citations