Skip to content
Open access

Limited utility of optic nerve sheath diameter for monitoring intracranial pressure in patients with intracranial hemorrhage

Oct 2026 · Frontiers in Neurology · Vol 17 · 0 citations · 26 references
Medicine

TL;DR

The findings question its reliability as a stand-alone tool for serial monitoring of dynamic ICP changes in treated neurocritical care patients and therefore should not be interpreted as a direct substitute for invasive ICP or as a stand-alone measure of short-term ICP change.

Abstract

Introduction Monitoring intracranial pressure (ICP) is a key component in the management of patients with intracranial hemorrhage. Transorbital ultrasound (toUS)- based measurement of the optic nerve sheath diameter (ONSD) - has been proposed as a non-invasive surrogate for ICP assessment. However, substantial variability in measurement techniques and cut-off values has raised concerns regarding its reliability. This study aimed to evaluate the association between repeatedly measured ONSD and invasively measured ICP in patients with intracranial hemorrhage and to assess the ability of ONSD to reflect changes in ICP over time. Methods In this prospective longitudinal study ONSD was measured daily using ultrasound at 3- and 6 mm posterior to the optic disc and compared with simultaneously recorded invasive ICP measurements. A total of 55 patients with intracranial hemorrhage were included, contributing repeated measurements over a mean of 5.47 ± 2.27 days. Results Overall, the association between ICP and ONSD was weak. In the prespecified primary analysis, ICP was not associated with bilateral mean irONSD at 3 mm (β = 0.004 mm per mmHg, 95% CI − 0.003 to 0.011; p = 0.169; marginal R2 = 0.3%). At 6 mm, a small but statistically significant relationship was detectable at bilateral ICP mean values for outer-reflection ONSD [β = 0.010, 95% CI (0.002–0.019), p = 0.016; marginal r2 = 1.3%]. Conclusion ICP explains less than 2% of the variance in ONSD in this treated cohort with predominantly controlled ICP. These findings question its reliability as a stand-alone tool for serial monitoring of dynamic ICP changes in treated neurocritical care patients and therefore should not be interpreted as a direct substitute for invasive ICP or as a stand-alone measure of short-term ICP change.

Read PDF

Similar papers

Open access Sep 2026

Ultrasound Measurement of Optic Nerve Sheath Diameter for Detection of Elevated Intracranial Pressure in Pediatric Encephalitis.

BACKGROUND AND OBJECTIVES Elevated intracranial pressure (ICP) is a critical and potentially life-threatening complication of pediatric encephalitis. Early detection is essential for improved outcomes. This study assessed the diagnostic utility of optic nerve sheath diameter (ONSD) ultrasound for identifying elevated I...

Duy Ngoc Le Huynh, T. Tran, Thuc Thanh Tran et al. · 0 citations
Open access Sep 2026

The optic nerve sheath diameter on ultrasound can only be used as a marker of intracranial pressure after comparison with a gold standard

It was concluded that ONSD measurement is a reliable method for identifying patients with elevated ICP and Cerebral computed tomography and clinical presentation are not sufficient standards for assessing ICP.

C. Scorza, F. Scorza, J. Finsterer · 0 citations
Open access Sep 2026

Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients

This study validates the clinical utility of ultrasound-derived ONSD indices in optimizing ICP assessment before craniotomy and proves they are reliable non-invasive biomarkers for predicting elevated ICP in neurocritical patients.

Guang-Zhao Li, Xiao-Wang Niu, Kai-Peng Zhang et al. · 0 citations
Open access Sep 2026

Utilizing transorbital ultrasound for assessment of intracranial pressure in traumatic brain injury patients

ONSD measured by bedside ultrasonography correlates inversely with neurological status and demonstrates responsiveness to therapeutic intervention in adult TBI, supporting its potential role as a practical, noninvasive adjunct to clinical neurological assessment.

Mohamed Elnokaly, Mohamed Gamal, S. Issa et al. · 1 citation
Review Open access 2026

Ultrasound Measurement of Optic Nerve Sheath Diameter in Acute Hypertensive States For Detection of Intracranial Involvement: A Meta-Analysis

Abstract Background: Detection of intracranial involvement in acute hypertension traditionally relies on fundoscopy, a method with limited applicability at the bedside. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) has emerged as a rapid, non-invasive alternative. Objective: To synthesize evide...

João Victor de Oliveira Ramos, Marcelo Tavares · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.