Skip to content

Development and ICH M10-compliant validation of an LC-MS/MS method for quantification of atirmociclib in mouse plasma and its application to preclinical pharmacokinetic studies.

Aug 2026 · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · Vol 1284, pp. 125271 · 0 citations · 10 references
Medicine

TL;DR

The first validated liquid chromatography tandem mass spectrometry (LC-MS/MS) bioanalytical method for the quantification of atirmociclib in mouse plasma is reported, validated in compliance with international council for harmonisation-M10 (ICH-M10) guidelines.

Abstract

Atirmociclib is a selective cyclin-dependent kinase 4 (CDK4) inhibitor currently under clinical investigation for the treatment of advanced malignancies, particularly hormone receptor positive (HR+) or human epidermal growth factor receptor 2 negative (HER2-) breast cancer. Here, we report the first validated liquid chromatography tandem mass spectrometry (LC-MS/MS) bioanalytical method for the quantification of atirmociclib in mouse plasma, validated in compliance with international council for harmonisation-M10 (ICH-M10) guidelines. Sample preparation involved a rapid and straightforward protein precipitation approach using acetonitrile, yielding consistent recovery (>80%) across low to high concentration levels. Chromatographic separation was achieved on a Kinetex C18 column (50 mm length × 2.1 mm internal diameter, 5 μm particle size) using gradient elution with 5 mM ammonium acetate in water (mobile phase A) and 0.1% v/v formic acid in acetonitrile (mobile phase B). The analyte (atirmociclib) and internal standard (warfarin) were detected using Q1/Q3 (m/z) mass transitions 464.2/303.9 and 309.0/163.0 respectively. The method demonstrated excellent selectivity, accuracy, precision, and linearity over a concentration range of 1-1000 ng/mL. Additionally, reliable quantification was maintained for samples exceeding the upper limit of quantification following up to 10-fold dilution. All validation parameters, including stability in biological matrices and solution, met the predefined acceptance criteria. This sensitive, and reproducible method was successfully applied to support preclinical pharmacokinetic study of atirmociclib in mouse, providing a valuable analytical tool.

View source

Similar papers

Open access Sep 2026

Development and Validation of a UPLC–MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies

A sensitive, reliable, and rapid UPLC–MS/MS method was developed and validated for the simultaneous determination of ensartinib and M465 in rat plasma and applied to a rat pharmacokinetic study and provides useful analytical support for further preclinical investigations of ensartinib and its major metabolite.

Shi-Qi Jiang, Yan Chen, Lu Cao et al. · 0 citations
Open access Sep 2026

LC–MS/MS Method Development and Validation for Quantification of Repotrectinib in Rat Plasma and its Application to Pharmacokinetic Study

The developed LC-MS/MS method for quantifying repotrectinib in rat plasma exhibited reliability and suitability for pharmacokinetic evaluation, as evidenced by a Cmax of 52.30±0.79 ng/ml at Tmax of 5 h in rats.

Sathish Sabbani, G. Chakravarthi, N. Malothu · 0 citations
Aug 2026

Simultaneous determination of bosutinib and its metabolite in rat plasma by UPLC-MS/MS: Development, validation and application to pharmacokinetic and metabolic stability studies.

In vivo pharmacokinetic studies confirmed that the UPLC-MS/MS method could be successfully used for the analysis of bosutinib after oral administration of 50 mg/kg in rats, and provides a potential reference for the clinical investigation of bosutinib.

Pei-Qi Wang, Yan Chen, Jun Wu et al. · 1 citation
#protein folding Open access Sep 2026

Quantification of Amlexanox in Beagle Dog Plasma by LC-MS/MS and Its Application in a Comparative Pharmacokinetic Study of Conventional and Sustained-Release Tablets.

The clinical development of a sustained-release amlexanox formulation with reduced dosing frequency and improved patient compliance is supported and support the clinical development of a sustained-release amlexanox formulation with reduced dosing frequency and improved patient compliance.

Yan-Mei Yi, Wei He, Xiao-Chen Niu et al. · 0 citations
Open access Aug 2026

Development and validation of a LC-MS/MS method for the quantification of the E-type prostanoid receptor 4 antagonist HTL0039732 in human plasma, for a Phase I/IIa clinical trial

ABSTRACT Background HTL0039732 (HTL) is a novel E-type prostanoid receptor 4 (EP4) antagonist for the treatment of advanced solid tumors. An analytical method was developed to facilitate the analysis of patient samples as part of an ongoing Phase I/IIa clinical trial. Methods and results A LC-MS/MS method for quantifyi...

Dan Astley, S. Svetlik, S. Barnett et al. · 0 citations
Open access Sep 2026

Development and validation of an LC-MS/MS method for the novel PROTAC KT-474 in rat and mouse plasma: Application to dose-dependent pharmacokinetics and metabolite identification in mice.

A sensitive liquid chromatography-tandem mass spectrometry method is developed and validated for the quantification of KT-474 in rat and mouse plasma and successfully applied it to pharmacokinetic studies in mice, providing a comprehensive characterization of the pharmacokinetic and metabolic properties of KT-474.

Ji-Hoon Oh, Dang-Khoa Vo, H. Maeng · 0 citations

Related blog posts

Google DeepMind Blog Sep 30, 2026

Introducing SynthID Bio

Proof of concept for watermarking AI-generated proteins while preserving biological function.

MIT News · Artificial Intelligence Aug 27, 2026

Looking beyond natural sequences

A new machine-learning framework aims to improve the success rate of computational protein design while moving away from results that reproduce sequences found in nature.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.