Skip to content
Conference Open access

PhysioCalib-Net: Adaptive Multimodal Deep Learning for Cuffless Blood Pressure Estimation and Hypertension Classification

Sep 2026 · 2026 10th International Conference on I-SMAC (IoT in Social, Mobile, Analytics and Cloud) (I-SMAC) · pp. 1719-1728 · 0 citations · 18 references

TL;DR

PhysioCalib-Net is introduced, a hybrid deep learning system that makes use of ECG and PPG data from the MIMIC-III Waveform Database in a synchronized way and allows for the simultaneous estimation of systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and the classification of hypertension stage.

Abstract

Cuffless blood pressure (BP) monitoring in a continuous manner is still a major challenge due to the inter-individual physiological differences, movement artifact issues, and the availability of accurate and interpretable algorithms. This paper introduces PhysioCalib-Net, a hybrid deep learning system that makes use of ECG and PPG data from the MIMIC-III Waveform Database in a synchronized way and allows for the simultaneous estimation of systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and the classification of hypertension stage. The proposed system features a preprocessing signal quality index (SQI) module, empirical mode decomposition (EMD) for motion artifacts suppression, beat-aligned segmentation followed by the Cross-Modal Attention Feature Fusion (CMAFF) module and a convolutional neural network (CNN)-Bidirectional Long-Short Term Memory (BiLSTM)-Light-weight Transformer encoder system. By combining blood pressure regression with hypertension classification into a multi-task learning approach, this framework highlights the importance of providing interpretable explanations thanks to the use of a SHAP-based explainability module. Besides, it has also been demonstrated that the framework is equipped with HL7 FHIR R4 for clinical compatibility. In the case study performed on the MIMIC-III dataset, subject-disjoint 5-fold cross-validation has shown experimental results of SBP MAE = 2.86 mmHg, DBP MAE = 1.98 mmHg, MAP MAE = 2.32 mmHg, and hypertension classification accuracy of 89.4%, being more efficient than the baseline methods and meeting the requirements of AAMI SP10. In total, the proposed model has 2.38 million parameters (9.13 MB) while the GPU inference latency is 14.2 ms.

Read PDF

Similar papers

Open access 2026

Improving the Accuracy of Volume-Compensation-Based Continuous Blood Pressure Measurement via Windkessel-Guided Multidomain Fusion

Hypertension is a major risk factor for cardiovascular diseases, and accurate and continuous blood pressure monitoring is crucial for early warning and personalized intervention. This study proposes a continuous noninvasive blood pressure monitoring method based on the Windkessel model and multifeature-domain fusion. A...

Shuai Ma, Zheng-Xu Yan, Cheng Peng et al. · 0 citations
Open access Oct 2026

Non-Invasive Blood Pressure Estimation Using Photoplethysmogram Morphological Features and Machine Learning

Continuous and unobtrusive blood pressure monitoring is vital for the early diagnosis and effective management of cardiovascular diseases. Conventional pneumatic cuffs cause physical discomfort during repeated measurements, while invasive catheterization poses substantial clinical risks. To overcome these limitations,...

Bing-Zhen Zhao · 0 citations
Review Open access Oct 2026

A narrative review of methods for estimating blood pressure waveforms from photoplethysmography.

Accurate, continuous blood pressure (BP) monitoring is important for preventing, diagnosing, and managing cardiovascular disease. Estimating the full arterial BP waveform can provide more clinical information than cuff-based measurements that report only systolic and diastolic BP. This review summarizes recent progress...

Bartosz Olszewski, C. Mataczyński, Z. Ostrowski et al. · 0 citations
Oct 2026

TPF-BP: A Three-Stage Physiology-Guided Self-Supervised Transfer Learning Framework for Personalized Blood Pressure Measurement.

Personalized and continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) is a critical requirement for next-generation wearable healthcare systems. Despite recent progress, existing PPG-based learning models exhibit limited generalization and personalization across individuals, hindering rob...

Yu-Hui Cen, Ren-Qi Chen, Xing Zhu et al. · 0 citations
Oct 2026

Personalized Blood Pressure Estimation With a Topological Prior Vector From Minimal Per-Subject Data

Cuffless blood pressure (BP) estimation from photoplethysmography (PPG) signals using deep learning (DL) has attracted significant attention for continuous, noninvasive health monitoring. However, traditional machine learning relies on handcrafted features that capture only limited aspects of the signal. While DL can l...

Myung-Kyu Yi, J. Lee, Jongshill Lee et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.