The effect of stratification ratio on combustion instability in a full-scale premixed arrayed micro-tube combustor
Abstract
Experiments were conducted on a full-scale premixed arrayed micro-tube hydrogen combustor to explore the effect of the stratification ratio (SR) on combustion instability. Four typical flame modes were observed. Attached main-stage flames were most frequently observed over SR = 0.8–1.5. At an air mass flow rate of 220 g/s and a total equivalence ratio of 0.300, the pressure amplitude exhibited a W-like local-extrema pattern for pilot equivalence ratios of 0.4 and 0.5. Under the same air mass flow rate and total equivalence ratio, the dominant frequency changed from approximately 480 Hz at SR < 0.8 to 420–450 Hz at SR > 0.8. These spectral changes are reported as observations rather than evidence of stage-wise acoustic-mode dominance. Further results indicate that high-amplitude oscillations concentrate in high-SR regions, and increasing pilot-stage equivalence ratio reduces pressure amplitude at SR > 1.6. The pressure amplitude rises significantly with global equivalence ratio, which lowers the critical SR for high-amplitude oscillations.