Skip to content

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

Jul 2026 · arXiv.org · Vol abs/2607.20136 · 0 citations · 71 references
Computer Science Physics

TL;DR

PRIME-SVR is presented, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI, which improves reconstruction sharpness, anatomical accuracy, and cross-TE structural consistency by 14%, and accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction.

Abstract

Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.

View source

Similar papers

Open access Aug 2026

Localized Quadratic RF Encoded Spin‐Echo With Spiral‐PRIME Reconstruction: A Practical Alternative to 3D FSE for High‐Resolution Volumetric Brain MRI

To extend localized quadratic (LQ) RF encoded spin‐echo imaging with acquisition and reconstruction strategies that improve efficiency and artifact robustness, positioning it as a practical alternative to 3D FSE for high‐resolution volumetric brain MRI.

Guruprasad Krishnamoorthy, J. Velikina, James G Pipe · 0 citations
Open access Sep 2026

Automated Brain Segmentation in Accelerated T2-Weighted MRI: Effects of Deep Learning-Based Reconstruction

Deep Resolve improved the robustness of automated brain segmentation in accelerated T2-weighted MRI, reducing cross-protocol variability and improving spatial reproducibility, with the largest reduction in reference-relative error in the most acceleration-sensitive pipeline.

J. Lasek, R. Obuchowicz, M. Strzelecki et al. · 0 citations
Preprint Aug 2026

Anatomically Consistent Cross-Contrast Super-Resolution of Anisotropic Brain T2w MRI

VIPP-SR (View-Independent Patched Projection Super-Resolution), a cross-contrast guided super-resolution framework that restores the inter-plane resolution of an existing anisotropic T2w volume without an isotropic ground-truth T2w, is proposed.

M. Shen, Haicheng Wang, Meghna Trivedi et al. · 0 citations
#diffusion models Preprint Aug 2026

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

CineDiff enabled high-quality reconstruction of highly accelerated 2D RT cine CMR and reduced block-like artifacts and preserved finer anatomical detail compared with traditional compressed sensing and a variational network method, termed CineVN.

Xuan Lei, Philip Schniter, Juliet Varghese et al. · 0 citations
Open access Aug 2026

Robust T1ρ, T2, and T2* mapping via spin-locked MOLED with synthetic data-driven deep learning reconstruction

SL-MOLED provides accurate, repeatable, and artifact-robust quantitative mapping within a substantially reduced acquisition time, offering a promising framework for reliable multi-parametric MRI with potential for clinical translation.

Wei-Kun Chen, Qing Lin, Tai-Shan Kang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.