Oct 2026· Italian National Conference on Sensors· Vol 26, pp. 6879· 0 citations· 30 references
TL;DR
The results demonstrate the technical feasibility of reference-assisted FBG sensing for simultaneous carotid–radial pulse-wave acquisition and preliminary PWV estimation and further validation requires higher-rate acquisition, repeated measurements, a larger cohort, and comparison with a reference PWV device.
Abstract
Simultaneous pulse-wave sensing at the carotid and radial arteries is challenging because the two sites require different mechanical coupling conditions and manually held carotid probes are susceptible to contact pressure and motion disturbances. This study presents a reference-assisted fiber Bragg grating (FBG) system comprising a wristband-type radial unit and a stamp-type carotid unit containing mechanically decoupled measurement and reference FBGs. Reference FBG regression (RFR) was used to suppress components shared by the carotid channels. In a 41.8 s recording from one male participant in his twenties, the reference and carotid measurement channels were essentially uncorrelated within the pulse-wave band (r = −0.05). After signal mean removal, RFR reduced power below 1 Hz by 74.3% without attenuating the pulse-band power (+11.4%), increasing the relative-power signal quality index from 0.174 to 0.458. Pulse transit time (PTT) was estimated by foot-centered windowed correlation. Analysis of 54 cardiac cycles yielded a representative PTT of 0.055 s. With an effective path length of 0.48 m, the corresponding pulse-wave velocity (PWV) was 8.7 m/s, with a within-record bootstrap 95% interval of 7.7–9.9 m/s. Estimates from eight non-overlapping 5 s segments were 9.1 ± 1.8 m/s. RFR produced lower segment-to-segment PTT variability than the baseline processing methods (coefficient of variation, 20.3% versus 34.6–46.7%). These results demonstrate the technical feasibility of reference-assisted FBG sensing for simultaneous carotid–radial pulse-wave acquisition and preliminary PWV estimation. Further validation requires higher-rate acquisition, repeated measurements, a larger cohort, and comparison with a reference PWV device.
Non-contact carotid pulse monitoring is a promising alternative to conventional contact-based methods by enabling continuous remote monitoring while improving patient comfort, reducing infection risk, and supporting telehealth applications. On the other hand, reliable contact-free detection of the carotid pulse remains...
Sagiru Gaya, K. Khalaf, A. S. M. Alqadami et al.· IEEE Access· 0 citations
This study presents a novel contactless method for beat-to-beat pulse interval estimation using 24 GHz millimeter-wave radar detection of radial artery surface motion. The proposed system employs Doppler effect principles to detect physiological micro-movements, incorporating comprehensive signal processing including b...
Tiếp Trí Vương, Y. Hoàng, Tuyen Trong Nguyen et al.· REV Journal on Electronics a...· 0 citations
Despite their commercial availability and portability, accelerometers (ACCs) are much less frequently used for arterial pulse waveform (APW) measurement, and the resulting acceleration pulse waveform (APWa) has been much less studied than the APW measured by a tactile sensor. This paper, the first of two parts, present...
Mamun Hasan, Zhi-Li Hao· Italian National Conference...· 0 citations
It is suggested that participant-specific reference information may improve Mobil-O-Graph-estimated PWV estimation across repeated measurements, as the model increasingly underestimated higher PWV values, indicating compression of the predicted range.
M. Cho, Soo Hyun Choi, Dong-Hun Kang et al.· 0 citations
Pulsed electromagnetic fields (PEMF) have been widely studied for vascular and microcirculatory modulation, yet their effects on pulsatile hemodynamic organization remain poorly characterized. It is also unclear whether reversing field direction under otherwise comparable exposure conditions can alter vascular waveform...
Ahmed Kiser, Tarikul Islam, Jubair Ibn Omar Hamza et al.· Biomedical engineering and p...· 0 citations