Effect of Load Variation on the Energy and Exergy Performance of the 2×50 MW Timor-1 Power Plant
Abstract
The effects of load variation on the stream energy and exergy, component performance, system efficiency, and the distributions of utilized exergy and exergy losses were investigated at Unit 2 of the Timor-1 Steam Power Plant, a 2 × 50 MW circulating fluidized bed (CFB) power plant. A descriptive-comparative quantitative approach was employed using operating data from performance tests at 50%, 75%, and 100% loads. The water–steam cycle was modeled using 18 streams and 10 components. Enthalpy and entropy were determined using the International Association for the Properties of Water and Steam (IAPWS) Industrial Formulation 1997. The results showed that increasing the load raised the energy and exergy rates of all streams. The main steam entering the turbine had the highest values: its energy rate increased from 110.96 to 213.49 MW, while its exergy rate increased from 106.49 to 206.13 MW. The turbine, condenser, and boiler exhibited the largest energy changes and stream exergy reductions. The system energy efficiency increased from 28.43% to 30.58%, whereas the system exergy efficiency increased from 29.04% to 31.23%. The utilized exergy remained stable at 64.46–65.46%. Therefore, operation at 100% load achieved the best thermodynamic conversion performance, as indicated by the highest system energy and exergy efficiencies.