Part of the reported deficit is bounded by representation geometry rather than by modelling quality, and much of the reported deficit is bounded by representation geometry rather than by modelling quality.
Abstract
Background/Objectives: Prototype-based few-shot segmentation is validated almost entirely on centimetre-scale abdominal organs; on pulmonary nodules, 70% of which are less than 10 mm in size, accuracy degrades sharply. We seek to determine how much of that degradation is geometric rather than methodological. Methods: No published method is trained or evaluated here. For any model whose prediction is a union of whole feature grid cells, the attainable Dice coefficient is bounded exactly by a single ratio ρ of the lesion diameter to the grid cell extent; bilinear upsampling relaxes it rather than removing it. We measured this bound on the 50% consensus masks of 2614 LIDC-IDRI nodules, quantified lesion preservation under six mask-handling policies, and swept a training-free implementation across fifteen input geometries. Results: Using SSL-ALPNet’s configuration, no whole-cell decision at that grid can exceed 19.0% Dice on the 5–8 mm band, which holds 44.6% of nodules, compared with 63–85% on abdominal organs. The governing size is the slice’s equal-area diameter, i.e., a median of 69% of the nominal value, which overstates the bound by 11.5 points. A lung mask used to erase rather than to locate destroys the lesion it should help find; hard masking removes more than half of 11.7% of the 180 nodules (95% CI 7.8–17.2). The swept implementation tracks the ceiling (r = 0.74 per episode), attaining 69% of the ceiling at the derived 32 mm tile compared with 8% at full-chest input; at a fixed cell size, it peaks at the encoder’s training resolution. Conclusions: Much of the reported deficit is bounded by representation geometry rather than by modelling quality. We provide a lesion-preserving formulation and derive the tile size from measurement rather than via a chosen margin.
NucShare is presented, a lightweight model whose shared decoder handles nuclear pixel segmentation, horizontal-vertical distance, and classification through learnable transposed convolutions for upsampling and three lightweight heads, using 37% of independent decoders' parameters with no loss in accuracy.
Wen-Yang Li, Xiang-Yang Jia, Wen-Long Zhong et al.· 0 citations
MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning, is proposed, and results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.
Jia-Ying Li, Paolo Remagnino· International Conference on...· 0 citations
A small-budget study whose contributions are two empirical observations rather than an architectural advance, in which a sum-of-parts gap is observed, not causally tested, and effect sizes and CIs are reported throughout.
Meyrem Hojamyradova, N. Ye· International Journal Of Eng...· 0 citations
Diabetic retinopathy (DR) lesions vary widely in shape, and microaneurysms (MAs) span only a few pixels. We hypothesize that modeling the spatial organization of lesion regions, with global context and shape-adaptive scanning, improves the segmentation of such small and irregular lesions. To test this, we propose D$^2$...
Chang-Shun Yu, Si-Qing Li, Yuan-Chen Liu et al.· 0 citations
Coarse-to-fine segmentation is a natural strategy for three-dimensional lesion delineation because full-resolution processing of an entire scan is expensive while only a small fraction of the volume contains pathology. Its main failure mode, however, is structural: a lesion missed by the coarse stage is usually absent...
Wan-Zhou Chen, Jia-Yi Chen· bioRxiv· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.