Image-Domain CT Metal Artifact Reduction Using an Endpoint-Conditioned Diffusion Bridge
Abstract
Background: Metal implants can generate severe streaking and shading artifacts in computed tomography (CT), obscuring nearby anatomy and altering local Hounsfield-unit (HU) values. Conventional diffusion models typically map images toward a Gaussian distribution and initialize reverse reconstruction from Gaussian noise, requiring the target image to be recovered through iterative denoising from an uninformative starting state. For CT restoration, this formulation does not directly exploit anatomical information already present in the metal-artifact image. Purpose: To adapt a diffusion bridge framework for image-domain CT metal artifact reduction (MAR) by directly connecting paired metal-artifact and metal-free CT images. The proposed RDBM-MAR model initializes reverse reconstruction from the metal-artifact CT image rather than Gaussian noise, aiming to retain available anatomical information and learn a direct restoration trajectory toward the metal-free target. Methods: RDBM-MAR constructs an endpoint-conditioned diffusion bridge between paired metal-free and metal-artifact CT images. During training, intermediate bridge states are generated between the two endpoints, and a conditional U-Net receives the bridge state, metal-artifact image, and timestep to estimate the metal-free CT image through an image-domain correction. The forward bridge used 100 timesteps, while inference used 10 deterministic reverse steps initialized from the metal-artifact image. Training, validation, and quantitative testing used 14,000 paired hybrid-simulated CT slices from the AAPM CT Metal Artifact Reduction Grand Challenge. These slices were derived from the DeepLesion dataset and the UCLH Stroke EIT Dataset, with virtual metal objects and artifacts generated using CatSim in the open-source XCIST toolkit. The data were divided into 12,045 training, 633 validation, and 1,322 held-out test slices. One case from the 29-case AAPM CT-MAR final scoring dataset was used for qualitative evaluation. RDBM-MAR was compared with CycleGAN, Pix2Pix, Res-SRDiff, I2I-Mamba, and I2SB using PSNR, SSIM, MAE, and LPIPS. Statistical analysis used the Friedman test followed by paired Wilcoxon signed-rank tests with Holm correction. Results: RDBM-MAR achieved the highest PSNR (43.67 ± 4.56 dB) and SSIM (0.9856 ± 0.0138) and the lowest MAE (14.74 ± 8.68 HU) among the evaluated methods. Significant between-method differences were observed for all four metrics (p < 0.001). Pairwise Wilcoxon signed-rank tests with Holm correction showed significantly better PSNR, SSIM, and MAE for RDBM-MAR than for all five comparison methods (adjusted p < 0.001). Res-SRDiff achieved the lowest LPIPS. Difference maps and HU line-profile analysis showed reduced artifact-related intensity errors with preservation of local anatomical structures. The AAPM final scoring case also showed qualitative reduction of visible metal-associated streaking. Conclusions: RDBM-MAR provides a direct restoration trajectory from the metal-artifact CT image toward the metal-free target while retaining anatomical information in the input. The proposed formulation achieved strong structural fidelity and HU accuracy on the held-out paired test set using 10 reverse sampling steps, supporting diffusion bridge modeling for image-domain CT MAR.