Skip to content
Open access

Eliminating Registration Bias in Synthetic CT Generation using a physics-based simulation framework for pelvic anatomy.

Aug 2026 · Physics in Medicine and Biology · Vol 71, pp. 175028 · 0 citations
Medicine

Abstract

OBJECTIVE Supervised synthetic computed tomography (sCT) generation from cone-beam CT (CBCT) requires spatially registered training pairs, yet perfect registration between separately acquired scans is unattainable. This registration bias propagates into trained models and corrupts intensity-based evaluation, so higher benchmark scores may reward reproduction of registration artifacts over anatomical fidelity. We propose physics-based CBCT simulation for geometrically aligned training pairs by construction, with bias-robust geometric metrics. Approach:A framework simulated pelvic CBCT from fan-beam CT, modeling respiratory motion, X-ray scatter, and noise to yield aligned simulated-CBCT/CT pairs. On a clinical gynecological dataset (deformable registration) and the SynthRAD2023 pelvic dataset (rigid registration), sCT models trained on simulated data were compared against models trained on real pairs, a finetuned variant, and CycleGAN and RegGAN baselines. Evaluation combined intensity metrics (MAE, PSNR, SSIM) with geometric alignment metrics (normalized mutual information, NMI; correlation coefficient, CC) against input CBCT. Downstream segmentation of bladder, rectum and bowel bag was assessed in two modes: an sCT cascade applying a CT-trained model to sCT outputs, and direct segmentation by a model trained on simulated CBCT, plus a physics ablation and five-observer quality assessment. Main results:Simulation-trained models achieved higher geometric alignment than real-trained models (cross-dataset NMI 0.31 vs 0.22) despite lower intensity scores. Intensity metrics correlated inversely with observer ratings under deformable registration, whereas NMI consistently predicted clinical preference (clinical ρ = 0.29, SynthRAD ρ = 0.31). Observers preferred simulation-trained outputs in 87% of cases. In the sCT cascade, simulation-trained models improved segmentation (DSC 0.91/0.86/0.54 vs 0.84/0.77/0.04), while direct simulation-trained CBCT segmentation reached 0.92/0.87/0.83, exceeding a phantom-based baseline on the bowel bag. Significance:Physics-based simulation eliminates registration bias at its source, and downstream segmentation provides a task-based measure of sCT conversion quality that intensity metrics miss. Geometric fidelity, not intensity agreement with biased ground truth, aligns with the spatial-accuracy requirements of adaptive radiotherapy.

Read PDF

Similar papers

Preprint Sep 2026

When Misalignment Becomes Supervision: Structured Label Noise in Supervised Synthetic CT Generation

Supervised synthetic CT (sCT) generation is commonly trained and evaluated as voxel-wise regression against registered reference CT images. In practice, MRI-CT and CBCT-CT pairs are aligned through registration procedures that leave residual misalignments. These residuals are not independent intensity noise but spatial...

Valentin Boussot, C. Hémon, C. Lafond et al. · 0 citations
Open access Sep 2026

Topology-preserved transformer-based CBCT-CT registration via normalized gradient field guidance for nasopharyngeal carcinoma

Summary Accurate deformable registration between planning CT (computed tomography) and cone-beam CT (CBCT) is essential for adaptive radiotherapy in nasopharyngeal carcinoma, but cross-modality intensity differences, low soft-tissue contrast, and CBCT artifacts complicate alignment. We propose NJTransMorph, an unsuperv...

Cheng-Jian Xiao, Wei-Xiang Lin, Fei-Long Tian et al. · 0 citations
Preprint Oct 2026

Anatomy-preserving unpaired cone-beam CT refinement for image-guided radiotherapy using pseudo-label guided diffusion

Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy, but scatter, beam hardening, noise, truncation, and other artifacts limit image quality and CT number accuracy. Paired CBCT and CT data are difficult to obtain clinically because of motion, anatomical changes, and acquisition mismatch. We...

Qi Lai, Yu-Tong He · 0 citations
Open access Sep 2026

A real-time metric for quantifying registration stability in mixed reality neurosurgical navigation.

OBJECTIVE Mixed reality (MR) guidance enables real-time superimposition of virtual anatomical models onto the surgical field but is inherently affected by spatial instability due to tracking limitations, sensor noise and head-mounted display dynamics. These frame-to-frame fluctuations may lead to transient mislocalisat...

Carlotta Fontana, M. de Notaris, G. Iaconetta et al. · 0 citations
Open access Aug 2026

Inverse‐consistent deformable image registration to propagate biomechanical constraints for online adaptive radiotherapy

A deformable image registration (DIR) framework is developed that integrates inverse consistency with local biomechanical constraints, enabling tissue‐specific motion modeling using contours from only a single image volume, yielding anatomically plausible motion estimates for ART workflows.

T. J. W. Draper, C. Zachiu, B. Raaymakers · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.